MITSUBISHI <INTELLIGENT POWER MODULES>
PM300DVA120
FLAT-BASE TYPE
INSULATED PACKAGE
THERMAL RESISTANCES
Symbol
Rth(j-c)Q
Rth(j-c)F
Rth(c-f)
Parameter
Junction to case Thermal
Resistances
Contact Thermal Resistance
Test Condition
Inverter IGBT part (per 1/2 module)
Inverter FWDi part (per 1/2 module)
Case to fin, Thermal grease applied (per 1/2 module)
Limits
Min.
Typ.
Max. Unit
—
—
0.099
—
—
0.13 °C/W
—
—
0.065
MECHANICAL RATINGS AND CHARACTERISTICS
Symbol
—
—
—
Parameter
Mounting torque
Mounting torque
Weight
Mounting part
Main terminal
Test Condition
screw : M6
screw : M8
Limits
Min.
Typ.
Unit
Max.
3.92 4.90
5.88 N • m
8.83 9.81
10.8 N • m
—
720
—
g
RECOMMENDED CONDITIONS FOR USE
Symbol
Parameter
Test Condition
Recommended value
Unit
VCC
Supply Voltage
Applied across C1-E2 terminals
≤ 800
V
VD
Control Supply Voltage
Applied between : VP1-VPC, VN1-VNC
(Note-3)
15 ± 1.5
V
VCIN(ON) Input ON Voltage
VCIN(OFF) Input OFF Voltage
Applied between : CPI-VPC, CNI-VNC
≤ 0.8
≥ 4.0
V
tdead
Arm Shoot-through
Blocking Time
For IPM’s each input signals
≥ 3.5
µs
fPWM
PWM Input Frequency
Using Application Circuit input signal of IPM, 3φ
Sinusoidal PWM VVVF inverter
≤ 20
kHz
(Note-3) With ripple satisfying the following conditions dv/dt swing ≤ ±5V/µs, Variation ≤ 2V peak to peak
Jun. 2005