Switching Specifications (AC)
Over Recommended Operating Conditions TA = 0°C to 70°C, VCC = 3 V to 18 V, unless otherwise specified.
Parameter
Device
Symbol HCPL- Min. Typ.* Max. Units
Test Conditions
Fig. Note
Propagation
tPHL
Delay Time
to Logic Low
at Output
65 500 µs IF = 40 µA, RL = 11 to 16 k,
VCC = 3.3 to 5 V
3 25
TA = 25°C
IF = 0.5 mA,
30
RL = 4.7 k
7, 9 9, 10
Propagation
tPLH
Delay Time
to Logic High
Output
4701/4731
70 500 µs IF = 40 µA, RL = 11 to 16 k,
VCC = 3.3 to 5 V
34 60
90
TA = 25°C
IF = 0.5 mA,
RL = 4.7 k
7, 9 9, 10
070A/073A
130
Common Mode
Transient
Immunity at
Logic High
Output
|CMH|
1,000 10,000
V/µs IF = 0 mA, RL = 4.7 to 11 k,
VCM = 10 Vp-p,
TA = 25°C,
8 6, 7
Common Mode
Transient
Immunity at
Logic Low
Output
|CML|
1,000 10,000
2,000
V/µs IF = 0.5 mA, RL = 4.7 to 11 k,
|VCM| = 10 Vp-p,
TA = 25°C
IF = 40 µA, RL = 11 to 16 k,
|VCM| = 10 Vp-p
VCC = 3.3 to 5 V, TA = 25°C
8 6, 7
*All typical values at TA = 25°C and VCC = 5 V, unless otherwise noted.
Package Characteristics
Parameter
Device
Symbol HCPL- Min. Typ.* Max. Units Test Conditions Fig. Note
Input-Output Momentary VISO
Withstand Voltage**
2500
Option 020
4701 5000
4731
V rms RH 50%,
t = 1 min.,
TA = 25°C
3, 4
3, 4a
Resistance
RI-O
(Input-Output)
1012
VI-O = 500 VDC
3
RH 45%
Capacitance
CI-O
(Input-Output)
0.6
pF f = 1 MHz
3
Insulation Leakage
II-I
4731
0.005
µA RH 45%, t = 5 s,
5
Current (Input-Input)
073A
VI-I = 500 VDC
Resistance (Input-Input)
RI-I
1011
Capacitance
CI-I 4731
0.03
pF f = 1 MHz
5
(Input-Input)
073A
0.25
*All typical values at TA = 25°C and VCC = 5 V.
**The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if appli-
cable), your equipment level safety specification or Agilent Application Note 1074 entitled “Optocoupler Input-Output Endurance
Voltage.”

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]