Cermetek Microelectronics, Inc.
CH1786 Family of Ultra Small 2400bps Modems
Table 2. CH1786 Pin Descriptions Continuation
PIN NAME TYPE
FUNCTION
18
HS
O
SPEED INDICATION. HIGH speed select output. A low on this pin indicates the
modem is operating at 2400bps.
19
VCC
-
POWER SUPPLY. 5 volts + 5% Note: Noise should be less than 50mV peak to
peak.
20
GND
21
RST1
-
GROUND. Note: Noise should be less than 50mV peak to peak.
I
RESET. Active HIGH. This input must be asserted HIGH for at least 10 ms to reset
the modem. RESET is then returned LOW for normal operation. If no system reset
is available, let this pin float to enable internal reset.
22
NC
-
No connection required. For CH179X or CH2056 compatibility, connect to GND or
use as an active LOW input for request to send (RTS) functionality for CH179X/2056
products.
Note: (1) If VCC has a slow power up ramp time, the internal reset may be ineffective.
(2) Do not drive LED’s directly from any output. Use Buffers.
Result Codes
0
1
2
3
4
5
6
7
10
Table 3. Summary of Result Codes and Meanings.
Status Message
Meaning
OK
Command Executed
CONNECT
Carrier detected at 300bps
RING
Ring Detected
NO CARRIER
Did not detect carrier
ERROR
Entry error
CONNECT 1200
Carrier detected at 1200bps
NO DIAL TONE
Off-hook, but no response after 5 seconds
BUSY
Busy signal detected
CONNECT 2400
Carrier detected at 2400bps
The escape sequence consists of a “guard time” (a
period where no characters are sent to the modem),
followed by 3 escape characters, followed by another
guard time. The guard time is set by register S12.
The escape character code is set in register S2. At
power-up, the guard time is set to 1 second minimum,
and the escape character is set as “+.” There is no
minimum delay between characters but the maximum
delay is set by register S12.
The CH1786 will stay off-hook with its carrier on after
the escape sequence is received. It will return an OK
status message when it is ready to accept
commands. The CH1786 may be put into data mode
by issuing the command ATO<CR>.
AT COMMAND APPLICATIONS
Dialing A Phone Number. The Dial command takes
the form Dn, where n is a string of characters. In the
simplest form, n will be only the digits of the phone
number to be dialed.
Example: Dial number.
Enter: ATD1234567<CR>