1122334455667788990011223344556677889900112233445566778899001122112233445566778899001122334455667788990011223344556677889900112211223344556677889900112233445566778899001122334455667788990011221122334455667788O9900c1122t33a44l5566D778899R0011e2233g44i55s66t77e8899r00s1122(1132233-44S5566t77a88t99e0011)22
DC Electrical Characteristics (Over the Operating Range, TA = –40°C to +85°C, VCC = 5.0V ± 5%)
Parameters Description
Test Conditions(1)
Min. Typ(2) Max. Units
VOH
Output HIGH Voltage VCC = Min., VIN = VIH or VIL
IOH = –15.0 mA
2.4 3.0
V
VOL
Output LOW Current VCC = Min., VIN = VIH or VIL
IOL = 64 mA
0.3 0.55 V
VOL
Output LOW Current VCC = Min., VIN = VIH or VIL
IOL = 12 mA (25Series)
0.3 0.50 V
VIH
Input HIGH Voltage Guaranteed Logic HIGH Level
2.0
V
VIL
Input LOW Voltage Guaranteed Logic LOW Level
0.8 V
IIH
Input HIGH Current VCC = Max.
VIN = VCC
1 µA
IIL
Input LOW Current VCC = Max.
VIN = GND
–1 µA
IOZH
High Impedance
VCC = MAX.
VOUT = 2.7V
1 µA
IOZL
Output Current
VOUT = 0.5V
–1 µA
VIK
Clamp Diode Voltage VCC = Min., IIN = –18 mA
–0.7 –1.2 V
IOFF
Power Down Disable VCC = GND, VOUT = 4.5V
— — 100 µA
IOS
Short Circuit Current VCC = Max.(3), VOUT = GND
–60 –120
mA
VH
Input Hysteresis
200
mV
Capacitance (TA = 25°C, f = 1 MHz)
Parameters(4)
Description
CIN
Input Capacitance
COUT
Output Capacitance
Test Conditions
VIN = 0V
VOUT = 0V
Typ
Max.
6
10
8
12
Notes:
1. For Max. or Min. conditions, use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at Vcc = 5.0V, +25°C ambient and maximum loading.
3. Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
4. This parameter is determined by device characterization but is not production tested.
Units
pF
pF
3
PS2016C 10/01/04