ADXL311
SPECIFICATIONS
Table 1. TA = 25oC, VDD = 3 V, RBIAS = 125 kΩ, Acceleration = 0 g, unless otherwise noted.)
Parameter
Conditions
Min Typ
SENSOR INPUT
Each Axis
Measurement Range
±2
Nonlinearity
Aligment Error1
Best Fit Straight Line
0.2
±1
Aligment Error
Cross Axis Sensitivity2
X Sensor to Y Sensor
0.01
±2
SENSITIVITY
Each Axis
Sensitivity at XFILT, YFILT
Sensitivity Change due to Temperature3
VDD = 3 V
Delta from 25°C
140 167
−0.025
ZERO g BIAS LEVEL
Each Axis
0 g Voltage XFILT, YFILT
0 g Offset vs. Temperature
VDD = 3 V
Delta from 25°C
1.2
1.5
2.0
NOISE PERFORMANCE
Noise Density
@25°C
300
FREQUENCY RESPONSE
3 dB Bandwidth
Sensor Resonant Frequency
At Pins XFILT, YFILT
6
10
FILTER
RFILT Tolerance
Minimum Capacitance
SELF TEST
32 kΩ Nominal
At Pins XFILT, YFILT
±15
1000
XFILT, YFILT
POWER SUPPLY
Self Test 0 to 1
45
Operating Voltage Range
2.7
Quiescent Supply Current
0.4
Turn-On Time
TEMPERATURE RANGE
160 × CFILT + 0.3
Operating Range
0
Max Units
g
% of FS
Degrees
Degrees
%
195 mV/g
%/°C
1.8 V
mg/°C
µg/√Hz RMS
kHz
kHz
%
pF
mV
5.25 V
1.0 mA
ms
70
°C
1 Alignment error is specified as the angle between the true and indicated axis of sensitivity (Figure 1).
2 Cross axis sensitivity is the algebraic sum of the alignment and the inherent sensitivity errors.
3 Defined as the output change from ambient to maximum temperature or ambient to minimum temperature.
Rev. A | Page 3 of 12