8-(1). Electrical life test (Motor free)
Sample: CM1aF-R-12V, 6pcs.
Load: 16 A 13.5 V DC
Cooling fan motor actual load (free condition)
Switching frequency: (ON:OFF = 2s:6s)
Ambient temperature: Room temperature
Circuit
13.5V
MM
Cooling fan motor
Load current waveform
Inrush current: 85A, Steady current: 18A,
20A
500ms
Change of pick-up and drop-out voltage
10
9
8
7
6
Pick-up voltage
Max.
5
Min.
4
3
Drop-out voltage
2
Max.
Min.
1
0
0
10
20
35
No. of operations, × 104
Change of contact resistance
CM
10
9
8
7
6
5
4
3
Max.
2
X
Min.
1
0
0
10
20
35
No. of operations, × 104
8-(2). Electrical life test (Halogen lamp load)
Sample: CM1aF-R-12V, 6pcs.
Load: 20A 13.5V DC
Switching frequency: (ON:OFF = 1s:14s)
Ambient temperature: Room temperature
Change of pick-up and drop-out voltage
10
9
8
7
6
Pick-up voltage
5
Max.
Min.
4
3
Drop-out voltage
Max.
2
Min.
1
00
5
10
No. of operations, × 104
Change of contact resistance
10
9
8
7
6
5
4
3
2
1
0
0
Max.
X
Min.
5
10
No. of operations, × 104
Cautions regarding the protection element
1. Part numbers without protection
elements
1) 12 V models
When connecting a coil surge protection
circuit to these relays, we recommend a
Zener diode with a Zener voltage of 24 V
or higher, or a resistor (680to 1,000).
When a diode is connected to the coil in
parallel, the release time will slow down
and working life may shorten. Before use,
please check the circuit and verify that
the diode is not connected in parallel to
the coil drive circuit.
2) 24 V models
When connecting a coil surge protection
circuit to these relays, we recommend a
Zener diode with a Zener voltage of 48 V
or higher, or a resistor (2,800to
4,700).
When a diode is connected to the coil in
parallel, the release time will slow down
and working life may shorten. Before use,
please check the circuit and verify that
the diode is not connected in parallel to
the coil drive circuit.
2. Part numbers with diodes
These relays use a diode in the coil surge
protection element. Therefore, the
release time is slower and the working life
might be shorter compared to part
numbers without protection elements and
part numbers with resistors.
Be sure to use only after evaluating under
actual load conditions.
3. Part numbers with resistors
This part number employs a resistor in
the coil surge protection circuit; therefore,
an external surge protection element is
not required. In particular, when a diode
is connected in parallel with a coil, the
revert time becomes slower which could
adversely affect working life. Please
check the circuit and make sure that a
diode is not connected in parallel with the
coil drive circuit.
For Cautions for Use, see Relay Technical Information.