datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

74LVC02A-Q100 데이터 시트보기 (PDF) - Nexperia B.V. All rights reserved

부품명
상세내역
일치하는 목록
74LVC02A-Q100
NEXPERIA
Nexperia B.V. All rights reserved NEXPERIA
74LVC02A-Q100 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Nexperia
74LVC02A-Q100
Quad 2-input NOR gate
7. Limiting values
Table 4. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Max
Unit
VCC
supply voltage
IIK
input clamping current
VI < 0 V
VI
input voltage
IOK
output clamping current
VO > VCC or VO < 0 V
VO
output voltage
output in HIGH or LOW-state
IO
output current
VO = 0 V to VCC
0.5
50
[1] 0.5
-
[2] 0.5
-
+6.5
V
-
mA
+6.5
V
50
mA
VCC + 0.5 V
50
mA
ICC
IGND
Ptot
Tstg
supply current
ground current
total power dissipation
storage temperature
Tamb = 40 C to +125 C
-
100
mA
100 -
mA
[3] -
500
mW
65
+150
C
[1] The minimum input voltage ratings may be exceeded if the input current ratings are observed.
[2] The output voltage ratings may be exceeded if the output current ratings are observed.
[3] For SO14 packages: above 70 C derate linearly with 8 mW/K.
For TSSOP14 packages: above 60 C derate linearly with 5.5 mW/K.
For DHVQFN14 packages: above 60 C derate linearly with 4.5 mW/K.
8. Recommended operating conditions
Table 5.
Symbol
VCC
VI
VO
Tamb
t/V
Recommended operating conditions
Parameter
Conditions
supply voltage
functional
input voltage
output voltage
output HIGH or LOW state
ambient temperature
input transition rise and fall rate VCC = 1.65 V to 2.7 V
VCC = 2.7 V to 3.6 V
Min
Typ
1.65
-
1.2
-
0
-
0
-
40
-
0
-
0
-
Max
3.6
-
5.5
VCC
+125
20
10
Unit
V
V
V
V
C
ns/V
ns/V
74LVC02A_Q100
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 4 April 2013
© Nexperia B.V. 2017. All rights reserved
4 of 14

Share Link: 