datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

WM8714 데이터 시트보기 (PDF) - Wolfson Microelectronics plc

부품명
상세내역
일치하는 목록
WM8714
Wolfson
Wolfson Microelectronics plc Wolfson
WM8714 Datasheet PDF : 17 Pages
First Prev 11 12 13 14 15 16 17
WM8714
Production Data
RIGHT JUSTIFIED MODE
The WM8714 supports word lengths of 16-bits in right justified mode.
In right justified mode, the digital audio interface receives data on the DIN input. Audio Data is
time multiplexed with LRCIN indicating whether the left or right channel is present. LRCIN is also
used as a timing reference to indicate the beginning or end of the data words.
In right justified mode, the minimum number of BCKINs per LRCIN period is 2 times the selected
word length. LRCIN must be high for a minimum of word length BCKINs and low for a minimum of
word length BCKINs. Any mark to space ratio on LRCIN is acceptable provided the above
requirements are met.
In right justified mode, the LSB is sampled on the rising edge of BCKIN preceding a LRCIN
transition. LRCIN is high during the left samples and low during the right samples.
LRCIN
BCKIN
1/fs
LEFT CHANNEL
RIGHT CHANNEL
DIN
123
14 15 16
MSB
LSB
Figure 4 Right Justified Mode Timing Diagram
123
MSB
14 15 16
LSB
AUDIO DATA SAMPLING RATES
The master clock for WM8714 supports audio sampling rates from 256fs and 384fs, where fs is
the audio sampling frequency (LRCIN) typically 32kHz, 44.1kHz, 48kHz, and 96kHz. The master
clock is used to operate the digital filters and the noise shaping circuits.
The WM8714 has a master clock detection circuit that automatically determines the relation
between the master clock frequency and the sampling rate (to within +/- 8 master clocks). If there
is a greater than 8 clocks error, the interface shuts down the DAC and mutes the output. The
master clock should be synchronised with LRCIN, although the WM8714 is tolerant of phase
differences or jitter on this clock.
SAMPLING
RATE
(LRCIN)
MASTER CLOCK
FREQUENCY (MHZ)
(MCLK)
256fs
384fs
32kHz
8.192
12.288
44.1kHz
11.2896
16.9340
48kHz
96kHz
12.288
24.5761
18.432
36.8641
Table 1 Master Clock Frequencies Versus Sampling Rate
Notes:
1. 96kHz sample rate at either 256fs or 384fs are only supported with 5V supplies.
w
PD Rev 4.0 November 2004