datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

VE-BAMD 데이터 시트보기 (PDF) - Vicor

부품명
상세내역
일치하는 목록
VE-BAMD Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
V375 DC-DC Converters
10 A
+IN
+OUT
C5
F1
+IN
F3
Input V1
L1
GND
L2/N
JMK Filter
P/N 1319-13
12.6 A*
L1
L2/N
1N4006
1N4006
Bridge
Rectifier
Vicor P/N 30660
Z1
Z2
Z3
Component Description
Designation
Vicor
Part Number
GATE IN
P/OK
R1
R2 D2
C9
GATE OUT VI-HAMD-xL
E/O
A/S
C1
D1
C2
D4
PC
PR
-IN
-OUT
-IN
10 A
+IN
+OUT
GATE IN
VI-BAMD-xL
GATE OUT
F2
R3 D3
C10
C4
D5
R4** C3
C6
C7
+IN
PC
PR
C1
C2, C3
0.1 μF ceramic, 50 V
0.01 μF ceramic, 50 V
-IN
-OUT
-IN
C4
Hold up capacitor,
Available as a HUB
C8
1000 to 6000 μF
from Vicor (see
adjoining table)
C5–C8
4,700 pF Y2 cap.
01000
C9,C10
0.2 μF, 500 V
Film or Ceramic
D1
D2, D3
D4, D5
F1, F2
1N4691 zener, 6.2 V
1N4006 diode, 800 V
00670
1N5817 schottky diode, 20 V
26108
Use recommended fusing for specific
DC-DC Converters
* Consult Vicor's Applications Engineering for specific
HAMD / BAMD filtering information.
** A 100 KΩ, 2 W resistor is used for every 1,000 μF
of hold up capacitance.
F3
20 A, 250 V
R1
50 KΩ
R2, R3
250 Ω, 0.25 W
R4**
V1
Z1, Z2
100 KΩ, 2 W
275 V MOV
130 V Transorb
30076
1.5KE130CA
Hold up Box (HUB)
2000 μF HUB1000-P 1350 W
Z3
150 V Transorb
1.5KE150CA
Figure 5 — Connection Diagram, HAMD / BAMD / V375 DC-DC Converters
HAMD-CL Driver HAM: No internal bridge rectifier or synchronization diodes.
BAMD-CL Booster HAM: Companion module to HAMD-CM used for additional output power. No internal bridge rectifier.
PIN FUNCTION / DESCRIPTION (CONT.)
A/S
The HAM provides a low voltage non isolated output Auxiliary
Supply (A/S) that may be used to power primary side control
and monitoring circuitry. This output is 19 – 23 Vdc, referenced
to -OUT, at 3 mA max. Do not overload or short this output as
the HAM will fail. A typical use for A/S is to power an optical
coupler that isolates the Power OK signal (Figure 6).
E/O
The Enable Output (E/O) is used to inhibit the DC-DC
converters at start up until the hold up capacitors are charged,
at which time Enable is asserted high (open state, Figure 8).
If the AC line fails, E/O goes low when the DC output of the
HAM drops below 250 Vdc.
E/O must be connected to the Gate Input of all VI-26x and
VI-J6x drivers and / or the PC pin of the V375 DC-DC converters
(Figure 4); failure to do so may cause the converters to toggle
on and off. If an external load is connected directly to the
output of the HAM, do not apply the load until the output hold
up capacitor(s) are fully charged.
In applications using VI-26x drivers and VI-26x boosters, the
E/O pin should be connected to the Gate In pin of the driver
module only, it is not necessary to connect this pin to boosters
as they are controlled by their respective driver.
The E/O pin ancillary circuitry illustrated in Figures 4 and 5
provides transient immunity. The illustrated circuitry is the
minimum required, see Figures 4 and 5.
+
19 – 23 V
+OUT
P/OK
E/O
A/S
–OUT
DO NOT OVERLOAD
or directly connect a capacitor
to the A/S terminal.
IAS 3 mA
+OUT
P/OK
E/O
A/S
–OUT
"Power OK" Status
Low = OK
18 kΩ, 1/4 W
Figure 6 — Auxiliary Supply (A/S)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 HAM, High-Boost Harmonic Attenuation Module
Set your site on VICOR at vicorpower.com
Rev. 2.5
Page 6 of 10

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]