ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
MODULE OPERATING SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Output voltage setpoint
Output OVP setpoint
Output Power
Efficiency
Min
18
27.72
31.5
86
Typ
24
28.00
32.7
87
Max
36
50
28.28
33.9
100
Unit
Vdc
Vdc
Vdc
Vdc
Watts
%
Notes
<100ms
Nominal input; full load; 25°C
25°C; recycle input voltage to restart ( 1 minute off )
At 100°C baseplate temp
Nominal input; 75% of full load; 25°C
MODULE INPUT SPECIFICATIONS
Parameter
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Dissipation, standby
Min
Typ
17.5
14.74
15.3
36.3
37.8
3.3
Max
Unit
17.9
Vdc
Vdc
39.6
Vdc
5.0
Watts
Notes
No load
MODULE OUTPUT SPECIFICATIONS
Parameter
Line regulation
Load regulation
Temperature regulation
Ripple and noise, p-p
Current limit
Short circuit current
Power sharing accuracy
Programming range
Min
3.64
.5.00
10
Typ
±0.02
±0.06
±0.002
85
4.12
4.12
±2
Max
±0.20
±0.20
±0.005
107
4.65
4.65
±5
110
Unit
%
%
% / °C
mV
Amps
Amps
%
%
Notes
Low line to high line; full load
No load to full load; nominal input
Over operating temperature range
Nominal input; full load; 20 MHz Bandwidth
Output voltage 95% of nominal
Output voltage <250mV
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,
contact Vicor Applications Engineering at 800-927-9474.
MODULE MECHANICAL SPECIFICATIONS
Baseplate
Slotted (Style 1)
Slotted baseplate (style 1) requires no designator.
For threaded baseplate add a "2" to the end of the
part number. For thru-hole add a "3".
Pin Style
Short (Style 1)
For long pin configuration add “L” to the end of the
part number. See page 7 for pin dimensions.
Vicor Corporation Tel: 800-735-6200 Fax: 978-475-6715 Data Sheet: V24C28C100A DC-DC Converter Date: 11-00 Rev. 2
Set your site on VICOR at www.vicr.com
Page 2 of 8