datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

TLP1255 데이터 시트보기 (PDF) - Toshiba

부품명
상세내역
일치하는 목록
TLP1255 Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
TLP1255 (C8,Q)
Recommended Connector
Mini CT connector (1.5 mm pitch, receptacle assembly / housing crimp type) made by
Tyco Electronics AMP, Ltd.
Housing-Terminal
En Bloc Type
Type
Receptacle
assembly
Housing crimp
Model
Number
353293-3
353908-3
Terminal Material
AWG Size
External Diameter
of Insulation
Coating
Phosphor bronze
AWG26 to 28 0.85 mm to 0.95 mm
Note 2: For further details of connector characteristics, please contact the relevant connector manufacturer.
Precautions
At power-on the internal circuit takes about 100 μs to stabilize. During this period any output signal would be unstable
and liable to change. Design the circuit so that no signal is output during this period.
The device when installed should be protected from interference by ambient light. The integrated phototransistor is
insensitive to light of 700 nm or less (e.g., fluorescent light), but is sensitive to light above 700 nm (e.g., incandescent
light). Detecting ambient light may cause the device to trigger a malfunction. Test and evaluate thoroughly any
end-equipment in which the device is used to ensure that no such interference will occur.
Take due care regarding the environment in which the device is to be installed. Oil or chemicals may cause the package
to melt or crack.
When attaching the device to the metal board, always hold the body of the device. Do not hold it by the connector.
Ensure that the board is flat, and not warped or twisted. Attach the device to a metal board at room temperature.
Toshiba recommends attaching the device to the smoother side of the board.
Toshiba recommends testing the attachment strength beforehand by actually attaching a device to the board.
Do not apply solder to the pins of the device connector. Make sure that the connector is linked to the Mini CT connector
or equivalent connector.
When inserting or removing the Mini CT connector or equivalent connector, always grasp the connector and its cable
firmly and either plug the connector into or pull it out of the device connector straight and not at an angle. Inserting or
removing the Mini CT connector or equivalent connector at an angle may cause damage to both the connector of the
device and the Mini CT connector or equivalent connector, resulting in an unreliable connection.
The leadframe of the package and the resistance are exposed, as shown below. Design the housing and chassis of
end-equipment with particular care to ensure that no conductive material or object (such as a metal pin) drops on the
leads of the leadframe or on both ends of the resistance terminal to cause a short circuit between them.
Top view
Connector
(6)
(1)
(7)
(2)
(3)
Resistance
Leads (1) to (5) of the leadframe and (6)
to (7) of the resistance terminal shown on
the left must not be shorted together
(4)
(5)
3
2007-10-01