datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

SX8744 데이터 시트보기 (PDF) - Semtech Corporation

부품명
상세내역
일치하는 목록
SX8744 Datasheet PDF : 24 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
SX8733/SX8743/SX8744
Digital temperature sensor
ADVANCED COMMUNICATIONS & SENSING
DATASHEET
Track resistances up to 1 kOhm may be cancelled. It is important that the track resistance values in the cathode or anode
path of the external sensor are made equal. Care must be taken during PCB layout to match track resistances between the
device and the sensor. Any resistance difference will lead to cancellation errors.
In this mode, VSS is used for the current return path from the cathode. This connection must be placed close to the diode’s
cathode. One port supply the current modulation to the anode and another port supply the cancellation current to the
cathode. The resulting junction voltage modulation is measured between the 2 used ports. Figure 5 explains the method:
Assume sensor Q1 is being measured in mode 2 with 3-point
I
P1
track resistance cancellation enabled. The PCB trace linking the
V1
device to the external sensor must be matched which means the
V2 PCB track resistance are the same. The same current is forced
P2
I
out of P1 and P2.
V1
The voltages developed on P1 and P2 traces are the same
2I
therefore the differential voltage seen on P1-P2 is not impacted by
VSS
the track resistance.
Figure 5. 3-Point Track Resistance Cancellation
3.5.3. The Kelvin (4-wire) Track Resistance Cancellation
Sense (+)
P1
The sensor is connected to the chip via 4 wires. Two comes from
the current source (force : P3, P4) and two are used for the
voltage measurement (sense : P1, P2).
P2
Sense (-)
P3
Force (+) I
P4
I
Force (-)
The Kelvin connection avoids the measurement error caused by
the voltage drop in the force path.
Sense leads are attached directly accross the external sensor.
The P1 and P2 connections must be as close as possible to
sensor anode and cathode respectively.
Figure 6. Kelvin (4-wire) Track Resistance Cancellation
3.6. Temperature Acquisition Sequence
The SX8743 monitors up to 4 sensors (3 remote and 1 internal). Theses can be scanned in sequence to make an
automatic reading of the sensors one after the other. The result of each conversion is stored in the temperature registers
(see Table 6). The register RegSensor defines which sensors are scanned in the sequence. When all the sensors are
selected, the sequence is the following: IntExt1Ext2Ext3Intetc.
ACS Revision 2.91/February 2010
©2010 Semtech Corp.
Page 11
www.semtech.com

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]