MITSUBISHI SOUND PROCESSOR ICs
M62475FP
AUTOMATIC ADJUSTMENT CD PREAMPLIFIER SERVO CONTROLLER
TRACK FUNCTION TABLE
INPUT
DATA
COMMAND
D3 D2
OUTPUT (SW Status)
TS SW
JF SW
TS OFF 0 0 OPEN (Servo OFF)
OFF
JR
0 1 OPEN (Servo OFF)
OFF
JF
1 0 OPEN (Servo OFF)
ON
TS ON 1 1 CLOSE (Servo ON)
OFF
JR SW
OFF
ON
OFF
OFF
SLEDGE FUNCTION LIST
INPUT
DATA
COMMAND
D1 D0
OUTPUT (SW status)
TS SW
SF SW
SS OFF 0 0 CLOSE (Sledge OFF) OFF
SR
0 1 CLOSE (Sledge OFF) OFF
SF
1 0 CLOSE (Sledge OFF) ON
SS ON 1 1 OPEN (Sledge ON)
OFF
JR SW
OFF
ON
OFF
OFF
DIRECT COMMAND FUNCTION
JP1 signal
When a 1-track jump takes place, serial data to be transferred
twice can be omitted to control the amount of delay in processing
time.
JP1 is generally set to "1". When JP1 is set to "0" with TC (Data
out) signal set to "1", the logic controller automatically reverses the
jump polarity (JF to JR or JR to JF).
When a jump is complete (after fixed time Ta), switching JP1 from
"0" to "1" can automatically terminate JF and JR to select the TR
ON/SSON status.
Signal Waveform with a jump
KICK PULSE (JF OR JR)
TS OUT
Ta
BRAKE PULSE
JP1
MITSUBISHI
ELECTRIC
( 11 / 19 )