Philips Semiconductors
9 V UHF mixer/oscillator for TV and VCR
tuners
Product specification
TDA5634T
handbook, full paguenwwidtahnted
signal
50 source
AC
AM = 30%
eu
1 kHz
HYBRID
50
B
wanted
ew
signal
source
D
50
AC
HYBRID
BD
50
CIN1 IFOUT1
D.U.T.
CIN2 IFOUT2
Vo
2x5
turns
FILTER
18 dB
attenuator
38.9 MHz
2
V Vmeas
turns
N1/N2 = 5 RMS
voltmeter
modulation
analyzer
50
MBH050
Vmeas = Vo 15.4 dB (transformer ratio N1/N2 = 5 and transformer loss).
Wanted output signal at fRFW: Vow = 108 dBµV, Vmeas = 92.6 dBµV.
Measuring the level of the unwanted output signal Vou causing 0.3 % AM modulation in the wanted output signal.
Vou = Vmeas + 15.4 dB.
fRFU = fRFW + 5.5 MHz; fosc = fRF + 38.9 MHz.
Filter characteristics: fc = 38.9 MHz; f3dBBW = 1.2 MHz; f30dBBW = 2.64 MHz.
Fig.5 Cross modulation measurement in band C.
handbook, full pagewidtuhnwanted
signal
source 50
AC
CIN1
LO1
eu Vmeas V
50
50
HYBRID
BD
Vi D.U.T.
CIN2
LO2
AC
HYBRID
BD
50
spectrum
analyzer
50
MBH051
Loss of the hybrid: 1 dB.
In band C: fRFW = 781 MHz. These wanted signals are not used during the measurement.
In band C: fosc = 819.9 MHz.
In band C: fRFU = 820 MHz = fRFW + 5 × 8 MHz 1 MHz.
Measuring the level of the unwanted signal Viu causing FM sidebands 30 dB below the oscillator carrier at the LO output.
Viu = Vmeas loss of the hybrid.
Fig.6 N + 5 1 MHz pulling measurement in band C.