PT6355
TIMING REQUIRMENTS
(Unless otherwise specified, VCC = 5 V, Ta = -20 to +85℃)
Parameter
Symbol
Reset input “L” pulse width
tw (/RESET)
Main clock input cycle time
(OSC1 input)
tc (OSC1)
Main clock input “H” pulse width
(OSC1 Input)
twH (OSC1)
Min.
2
192
60
Typ.
Main clock input “L” pulse width
(OSC1 Input)
twL (OSC1)
60
Serial clock input cycle timeNote2
tc (SCLK)
5
Serial clock input “H” pulse widthNote2
twH (SCLK)
2
Serial clock input “L” pulse widthNote2
twL (SCLK)
3
Serial input set-up timeNote2
tsu (SIN-SCLK)
2
Serial input hold timeNote2
th (SCLK-SIN)
3
Serial input set-up time
tsu (/CS)
50tc (OSC1)
Serial input hold time
th (/CS)
50tc (OSC1)
Serial clock interval time
trec (SCLK)
50tc (OSC1)
Notes:
1. tc (OSC1) = 1/fosc
2. The unit means the number of Noise Filter Sampling Clock [2 x tc (OSC1)]
3. Test Mode Frequency Measurement (refer to diagram):
a. fosc= 2 x Frequency Value outputted by the CS Pin.
b. twH (SCLK) = [(1/fosc) x 2] x 2
c. twL (SCLK) = [(1/fosc) x 2 ] x 3
d. trec (SCLK) = [50 x (1/fosc)]
e. twH (SCLK), twL (SCLK) & trec (SCLK) are very important factors in writing the PT6355 software program.