MITSUBISHI SEMICONDUCTOR <Application Specific Intelligent Power Module>
PS11015
FLAT-BASE TYPE
INSULATED TYPE
ELECTRICAL CHARACTERISTICS (Tj = 25°C, VDH = 15V, VDB = 15V unless otherwise noted)
Symbol
Item
Condition
Ratings
Min.
Typ.
Max. Unit
IDH
Vth(on)
Circuit current
Input on threshold voltage
VDH = 15V, VCIN = 5V
150 mA
0.8
1.4
2.0
V
Vth(off)
Ri
fPWM
Input off threshold voltage
Input pull-up resistor
PWM input frequency
Integrated between input terminal-VDH
TC 100°C, Tj 125°C
2.5
3.0
4.0
V
150
k
2
20
kHz
txx
tdead
tint
Allowable input on-pulse width
Allowable input signal dead time for
blocking arm shoot-through
Input inter-lock sensing
VDH = 15V, TC = –20°C ~ +100°C (Note 3)
1
Relates to corresponding input
(Except brake part) TC = –20°C ~ +100°C
2.2
Relates to corresponding input (Except brake part)
500
µs
µs
65
100
ns
VCO
VC+(200%)
Analogue signal linearity with
output current
VC–(200%)
|VCO| Offset change area vs temperature
VC+
Analogue signal output voltage limit
VC–
Ic = 0A
VDH = 15V
1.87 2.27 2.57
V
Ic = IOP(200%)
TC = –20°C ~ +100°C 0.77
1.17
1.47
V
Ic = –IOP(200%)
(Fig. 4) 2.97 3.37 3.67
V
VDH = 15V, TC = –20°C ~ +100°C
15
mV
Ic > IOP(200%), VDH = 15V
0.7
V
(Fig. 4) 4.0
V
VC(200%) Analogue signal over all linear variation |VCO-VC±(200%)|
1.1
V
rCH
Analogue signal data hold accuracy
Correspond to max. 500µs data hold period
only, Ic = IOP(200%)
(Fig. 5)
–5
5
%
td(read)
±IOL
ICL(H)
ICL(L)
Analogue signal reading time
After input signal trigger point
(Fig. 8) —
3
µs
Current limit warning (CL) operation level VDH =15V, TC = –20°C ~ +100°C (Note 4) 20.35 24.70 29.00
A
Signal output current of
CL operation
Idle
Active
Open collector output
1
µA
1
mA
SC
Short circuit over current trip level
Tj = 25°C
(Fig. 7) (Note 5) 30.0 53.0 76.0
A
OT
Trip level
Over temperature protection
VDH =15V
OTr
Reset level
100
110
120
°C
90
°C
UVDH
Trip level
11.05 12.00 12.75 V
UVDHr
Reset level
11.55 12.50 13.25 V
OVDH
OVDHr
UVDB
Supply circuit under &
over voltage protection
Trip level
Reset level
Trip level
TC = –20°C ~ +100°C
Tj 125°C
18.00 19.20 20.15 V
16.50 17.50 18.65 V
10.0 11.0 12.0
V
UVDBr
tdV
Reset level
Filter time
10.5 11.5 12.5
V
10
µs
IFO(H)
IFO(L)
Fault output current
Idle
Active
Open collector output
1
µA
1
mA
(Note 3) : (a) Allowable minimum input on-pulse width : This item applies to P-side circuit only.
(b) Allowable maximum input on-pulse width : This item applies to both P-side and N-side circuits excluding the brake circuit.
(Note4) : CL output : The "current limit warning (CL) operation circuit outputs warning signal whenever the arm current exceeds this limit. The
circuit is reset automatically by the next input signal and thus, it operates on a pulse-by-pulse scheme.
(Note5) : The short circuit protection works instantaneously when a high short circuit current flows through an internal IGBT rising up momen-
tarily. The protection function is, thus meant primarily to protect the ASIPM against short circuit distraction. Therefore, this function is
not recommended to be used for any system load current regulation or any over load control as this might, cause a failure due to
excessive temperature rise. Instead, the analogue current output feature or the over load warning feature (CL) should be appropri-
ately used for such current regulation or over load control operation. In other words, the PWM signals to the ASIPM should be shut
down, in principle, and not to be restarted before the junction temperature would recover to normal, as soon as a fault is feed back
from its FO1 pin of the ASIPM indicating a short circuit situation.
RECOMMENDED CONDITIONS
Symbol
Item
VCC
Supply voltage
VDH, VDB Control supply voltage
VDH, VDB
VCIN(on)
VCIN(off)
fPWM
tdead
Supply voltage ripple
Input on voltage
Input off voltage
PWM Input frequency
Arm shoot-through blocking time
Condition
Applied across P2-N terminals
Applied between VDH-GND, CBU+-CBU–, CBV+-CBV–,
CBW+-CBW–
Using application circuit
Using application circuit
Ratings
400 (max.)
15±1.5
±1 (max.)
0 ~ 0.3
4.8 ~ 5.0
2 ~ 20
2.2 (min.)
Unit
V
V
V/µs
V
V
kHz
µs
Jan. 2000