Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Symbol
Power Device Junction Temperature
Tj
Storage Temperature
Tstg
Case Operating Temperature
TC
Mounting Torque, M6 Mounting Screws
—
Mounting Torque, M8 Main Terminal Screws
—
Module Weight (Typical)
—
Supply Voltage Protected by OC and SC (VD = 13.5 - 16.5V, Inverter Part)
Isolation Voltage (Main Terminal to Baseplate, AC 1 min.)
VCC(prot.)
Viso
Control Sector
Supply Voltage (Applied between VP1-VPC, VN1-VNC)
Input Voltage (Applied between CP1-VPC, CN1-VNC)
Fault Output Supply Voltage (Applied between Fpo-Vpc and Fno-Vnc)
Fault Output Current (Sink Current at FPO, PNO Terminal)
VD
VCIN
VFO
IFO
IGBT Inverter Sector
Collector-Emitter Voltage (VD = 15V, VCIN = 5V)
Collector Current, (Tc = 25°C)
Peak Collector Current, (Tc = 25°C)
Supply Voltage (Applied between C1 - E2)
Supply Voltage, Surge (Applied between C1 - E2)
Collector Dissipation
VCES
IC
ICP
VCC
VCC(surge)
PC
Ratings
-20 to 150
-40 to 125
-20 to 100
3.92~5.88
8.83~10.8
910
800
2500
20
10
20
20
1200
300
600
900
1000
1790
Units
°C
°C
°C
N·m
N·m
Grams
Volts
Vrms
Volts
Volts
Volts
mA
Volts
Amperes
Amperes
Volts
Volts
Watts