8-Channel Fault-Protected Analog Multiplexer
358
TABLE 3. 358 ELECTRICAL CHARACTERISTICS
(V+ = 15V, V- = -15V, VAH = 2.4V, VAL = 0.8V, TA = -55 TO +125°C, UNLESS OTHERWISE SPECIFIED)
PARAMETER
TEST CONDITIONS
SUBGROUPS SYMBOL TEMP
MIN
TYP
MAX
STATIC
ON Resistance
VD = ±10V, IS = ±100µ A
VAL = 0.8V, VAH = 2.4V
OFF Input Leakage Cur- VS = ±10V, VD = +10V
rent
VEN = 0.8V
OFF Output Leakage
Current
VD = ±10V, VS = +10V
VEN = 0.8V
ON Channel Leakage
Current
VS(ALL) = VD = ±10V1
VAH = VEN = 2.4V
VAL = 0.8V
Analog Signal Range 2
FAULT
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
rDS(ON)
IS(OFF)
ID(OFF)
ID(ON)
+25°C
Full
+25°C
Full
+25°C
Full
+25°C
Full
1, 2, 3
VAN
Full -15
Output Leakage Current VD = 0V1
(with Overvoltage)
Analog Overvoltage =
± 33V
1, 2, 3
ID(OFF) +25°C
Full
Input Leakage Current VIN = ±25V, VO = ±10V1
(with Overvoltage)
1, 2, 3
IS(OFF) +25°C
Input Leakage Current VIN = ±25V, VEN = VO = 0V
(w/ Power Supplies Off) AO = A1 = A2 = OV or 5V
INPUT
1, 2, 3
IS(OFF) +25°C
Input Low Threshold
Input High Threshold
Input Leakage Current
(High or Low)
VA = 4V or 0V3
1, 2, 3
VAL
Full
1, 2, 3
VAH
Full 2.4
1, 2, 3
IA
Full
DYNAMIC
Access Time
Break-Before-Make
Delay
Enable Delay (ON)
VEN = ±5V, VIN = ±10V
AO, A1, A2 Strobed
1, 2, 3
tA
+25°C
9, 10, 11 ton-toff +25°C 25
9, 10, 11
ton(EN)
+25°C
Full
1.2 1.5
1.5 1.8
0.03
50
0.1
200
0.1
2002
15
4.0
2.0
5.0
2.0
0.8
1.0
0.5 1.0
80
300 500
1000
Enable Delay (OFF)
Setting Time: (0.1%)
(0.01%)
“OFF Isolation”4
VEN = 0.8V, RL = 1k
CL = 15pF, V = 7VRMS
f = 100kHz
9, 10, 11
9, 10, 11
toff(EN)
tsett
+25°C
Full
+25°C
4, 5, 6
+25°C 50
300 500
1000
1.2
3.5
68
UNITS
k
nA
nA
nA
V
nA
µA
µA
µA
V
V
µA
µs
ns
ns
ns
µs
db
02.06.04 Rev 3
All data sheets are subject to change without notice 3
©2004 Maxwell Technologies
All rights reserved.