Philips Semiconductors
8-bit shift register with output register
Product specification
74HC/HCT594
DC CHARACTERISTICS FOR
74HCT
For the DC characteristics, see
“74HC/HCT/HCU/HCMOS Logic
Family Specifications”.
Output capability: parallel outputs,
bus driver; serial output, standard.
ICC category: MSI.
Note to HCT types
The value of additional quiescent
supply current (ICC) for a unit load of
1 is given in the family specifications.
To determine ICC per input, multiply
this value by the unit load coefficient
shown in the following table.
INPUT
Ds
SHR
SHCP
STCP
STR
UNIT LOAD
COEFFICIENT
0.25
1.50
1.50
1.50
1.50
AC CHARACTERISTICS FOR 74HCT
GND = 0 V; tr = tf = 6 ns; CL = 50 pF.
Tamb (°C)
TEST CONDITIONS
SYMBOL
PARAMETER
+25
40 to +85 40 to +125 UNIT VCC WAVEFORMS
min. typ. max. min. max. min. max.
(V)
tPHL/tPLH propagation delay
SHCP to Q7
18 32 40
propagation delay
18 32 40
STCP to Qn
tPHL
propagation delay
17 30 38
SHR to Q7
propagation delay
17 30 38
STR to Qn
tW
shift clock pulse width 16 4 20
HIGH or LOW
storage clock pulse
width HIGH or LOW
16 4
20
shift and storage reset 16 6
pulse width HIGH or
LOW
20
tsu
set-up time Ds to SHCP 20 4
25
48 ns
48 ns
45 ns
45 ns
24
ns
24
ns
24
ns
30
ns
4.5 Fig.7
4.5 Fig.8
4.5 Fig.11
4.5 Fig.12
4.5 Fig.7
4.5 Fig.8
4.5 Fig.11 and Fig.12
4.5 Fig.9
set-up time
20 6 25
30
ns 4.5 Fig.10
SHR to STCP
set-up time
20 7 25
30
ns 4.5 Fig.8
SHCP to STCP
th
hold time Ds to SHCP 5
3
6
7
ns 4.5 Fig.9
trem
removal time
SHR to SHCP,
STR to STCP
fmax
maximum clock
frequency
SHCP or STCP
10 5 13
15
ns 4.5 Fig.11 and Fig.12
30 92 24
20
MHz 4.5 Fig.7 and Fig.8
December 1991