RHRG7560
Electrical Specifications TC = 25oC, Unless Otherwise Specified
SYMBOL
TEST CONDITION
MIN
TYP
MAX
UNITS
VF
IF = 75A
IF = 75A, TC = 150oC
-
-
2.1
V
-
-
1.7
V
IR
VR = 600V
VR = 600V, TC = 150oC
-
-
250
µA
-
-
2.0
mA
trr
IF = 1A, dIF/dt = 200A/µs
-
-
55
ns
IF = 75A, dIF/dt = 200A/µs
-
-
60
ns
ta
IF = 75A, dIF/dt = 200A/µs
-
27
-
ns
tb
IF = 75A, dIF/dt = 200A/µs
-
23
-
ns
QRR
IF = 75A, dIF/dt = 200A/µs
-
140
-
nC
CJ
RθJC
VR = 10V, IF = 0A
-
200
-
pF
-
-
0.8
oC/W
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300µs, D = 2%).
IR = Instantaneous reverse current .
trr = Reverse recovery time (See Figure 9), summation of ta + tb.
ta = Time to reach peak reverse current (See Figure 9).
tb = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 9).
QRR = Reverse recovery charge.
CJ = Junction Capacitance.
RθJC = Thermal resistance junction to case.
pw = pulse width.
D = duty cycle.
Typical Performance Curves
300
100
100oC
175oC
10
25oC
1
0
0.5
1.0
1.5
2.0
2.5
3.0
VF, FORWARD VOLTAGE (V)
FIGURE 1. FORWARD CURRENT vs FORWARD VOLTAGE
5000
1000
175oC
100
100oC
10
1
25oC
0.1
0.01
0
100
200
300
400
500
600
VR, REVERSE VOLTAGE (V)
FIGURE 2. REVERSE CURRENT vs REVERSE VOLTAGE