datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

5962-8777101M3A 데이터 시트보기 (PDF) - Analog Devices

부품명
상세내역
일치하는 목록
5962-8777101M3A Datasheet PDF : 16 Pages
First Prev 11 12 13 14 15 16
APPLICATIONS
The OP400 is inherently stable at all gains and is capable of
driving large capacitive loads without oscillating. Nonetheless,
good supply decoupling is highly recommended. Proper supply
decoupling reduces problems caused by supply line noise and
improves the capacitive load-driving capability of the OP400.
Total supply current can be reduced by connecting the inputs of
an unused amplifier to V−. This turns the amplifier off,
lowering the total supply current.
DUAL LOW POWER INSTRUMENTATION
AMPLIFIER
A dual instrumentation amplifier that consumes less than
33 mW of power per channel is shown in Figure 30. The linear-
ity of the instrumentation amplifier exceeds 16 bits in gains of 5 to
200 and is better than 14 bits in gains from 200 to 1000. CMRR
is above 115 dB (G = 1000). Offset voltage drift is typically
0.4 μV/°C over the military temperature range, which is
comparable to the best monolithic instrumentation amplifiers.
The bandwidth of the low power instrumentation amplifier is
a function of gain and is shown in Table 6.
The output signal is specified with respect to the reference
input, which is normally connected to analog ground. The
reference input can be used to offset the output from −10 V to
+10 V if required.
OP400
Table 6. Gain Bandwidth
Gain
5
10
100
1000
Bandwidth
150 kHz
67 kHz
7.5 kHz
500 Hz
+
VIN
+
1/4
OP400A
+
1/4
OP400A
VOUT
REFERENCE
20k
5k
5k
RG
+
VIN
+
1/4
OP400A
20k
VOUT
40,000
VIN = 5 + RG
+
1/4
OP400A
VOUT
REFERENCE
5k
20k
5k
20k
RG
Figure 30. Dual Low Power Instrumentation Amplifier
Rev. E | Page 11 of 16