NJW1327
„CHARACTERISTICS OF BUS LINES (SDA, SCL) FOR I2C BUS DEVICES
PARAMETER
SCL clock frequency
Hold time (repeated) START condition.
Low period of the SCL clock
High period of the SCL clock
Set-up time for a repeated START condition
Data hold time NOTE)
Data set-up time
Rise time of both SDA and SCL signals
Fall time of both SDA and SCL signals
Set-up time for STOP condition
Bus free time between a STOP and START condition
Capacitive load for each bus line
Noise margin at the Low level
Noise margin at the High level
SYMBOL
fSCL
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tr
tf
tSU:STO
tBUF
Cb
VnL
VnH
Standard mode
Fast mode
MIN. TYP. MAX. MIN. TYP. MAX.
UNIT
-
-
100
-
-
400
kHz
4.0
-
-
0.6
-
-
µs
4.7
-
-
1.3
-
-
µs
4.0
-
-
0.6
-
-
µs
4.7
-
-
0.6
-
-
µs
0
-
-
0
-
-
µs
250
-
-
100
-
-
ns
-
- 1000 -
-
300
ns
-
-
300
-
-
300
ns
4.0
-
-
0.6
-
-
µs
4.7
-
-
1.3
-
-
µs
-
-
400
-
-
400
pF
0.5
-
-
0.5
-
-
V
1
-
-
1
-
-
V
Cb ; total capacitance of one bus line in pF.
NOTE). Data hold time: tHD:DAT
Hold the Data Hold Time (tHD:DAT) to 300ns or more to avoid status of unstable at SCL falling edge.