NJW1154
s CONTROL COMMAND TABLE
a) Master Volume
Select
BIT
Address
D7
D6
D5
D4
D3
D2
D1
D0
00H
01H
Don’t Care
Don’t Care
VOLa
VOLb
•VOLa / VOLb : Ach and Bch volume level setting from +12dB to -12dB with 3dB step.
VOLa / VOLb
Gain (dB)
D3
D2
D1
D0
+12
0
0
0
0
+9
0
0
0
1
+6
0
0
1
0
+3
0
0
1
1
0
0
1
0
0
-3
0
1
0
1
-6
0
1
1
0
-9
0
1
1
1
-12
1
0
0
0
Mute
1
1
1
1
b)Input Selector
Select
Address
D7
02H
D6
D5
Don’t Care
•Selector : Input signal selecting
BIT
D4
D3
D2
D1
D0
Selector
Selector
Input
D2
D1
D0
L1IN / R1IN
0
0
0
L2IN / R2IN
0
0
1
L3IN, L4IN / R3IN, R4IN
0
1
0
L5IN / R5IN
0
1
1
L6IN / R6IN
1
0
0
L7IN / R7IN
1
0
1
–6–
[CAUTION]
The specifications on this databook are only
given for information , without any guarantee
as regards either mistakes or omissions. The
application circuits in this databook are
described only to show representative usages
of the product and not intended for the
guarantee or permission of any right including
the industrial rights.