(4) PWM DIMMING CONTROL
By setting the duty data at “PWM REGISTER” bits, 8 out of 64 registers are assigned to the PWM
REGISTER 0-7. The PWM duty is changed depending on the register selected by the SENS voltage. The relation
between the PWM REGISTER and its duty is shown below.
TABLE 1 PWM DUTY vs. PWM REGISTER
REGISTER
DUTY
REGISTER
0,0,0,0,0,0
OFF
0,1,0,0,0,0
0,0,0,0,0,1
3.13%
0,1,0,0,0,1
0,0,0,0,1,0
4.69%
0,1,0,0,1,0
0,0,0,0,1,1
6.25%
0,1,0,0,1,1
0,0,0,1,0,0
7.81%
0,1,0,1,0,0
0,0,0,1,0,1
9.38%
0,1,0,1,0,1
0,0,0,1,1,0
10.94%
0,1,0,1,1,0
0,0,0,1,1,1
12.50%
0,1,0,1,1,1
0,0,1,0,0,0
14.06%
0,1,1,0,0,0
0,0,1,0,0,1
15.63%
0,1,1,0,0,1
0,0,1,0,1,0
17.19%
0,1,1,0,1,0
0,0,1,0,1,1
18.75%
0,1,1,0,1,1
0,0,1,1,0,0
20.31%
0,1,1,1,0,0
0,0,1,1,0,1
21.88%
0,1,1,1,0,1
0,0,1,1,1,0
23.44%
0,1,1,1,1,0
0,0,1,1,1,1
25.00%
0,1,1,1,1,1
DUTY
26.56%
28.13%
29.69%
31.25%
32.81%
34.38%
35.94%
37.50%
39.06%
40.63%
42.19%
43.75%
45.31%
46.88%
48.44%
50.00%
REGISTER
1,0,0,0,0,0
1,0,0,0,0,1
1,0,0,0,1,0
1,0,0,0,1,1
1,0,0,1,0,0
1,0,0,1,0,1
1,0,0,1,1,0
1,0,0,1,1,1
1,0,1,0,0,0
1,0,1,0,0,1
1,0,1,0,1,0
1,0,1,0,1,1
1,0,1,1,0,0
1,0,1,1,0,1
1,0,1,1,1,0
1,0,1,1,1,1
DUTY
51.56%
53.13%
54.69%
56.25%
57.81%
59.38%
60.94%
62.50%
64.06%
65.63%
67.19%
68.75%
70.31%
71.88%
73.44%
75.00%
REGISTER
1,1,0,0,0,0
1,1,0,0,0,1
1,1,0,0,1,0
1,1,0,0,1,1
1,1,0,1,0,0
1,1,0,1,0,1
1,1,0,1,1,0
1,1,0,1,1,1
1,1,1,0,0,0
1,1,1,0,0,1
1,1,1,0,1,0
1,1,1,0,1,1
1,1,1,1,0,0
1,1,1,1,0,1
1,1,1,1,1,0
1,1,1,1,1,1
DUTY
76.56%
78.13%
79.69%
81.25%
82.81%
84.38%
85.94%
87.50%
89.06%
90.63%
92.19%
93.75%
95.31%
96.88%
98.44%
100.00%
The relation between the PWM REGISTER and SENS voltage is reversed by the “REV” bit, as follows.
TABLE 2 REV vs. PWM REGISTER
REV
PWM REGISTER
PWM REGISTER0
PWM REGISTER1
PWM REGISTER2
0
PWM REGISTER3
PWM REGISTER4
PWM REGISTER5
PWM REGISTER6
PWM REGISTER7
PWM REGISTER7
PWM REGISTER6
PWM REGISTER5
1
PWM REGISTER4
PWM REGISTER3
PWM REGISTER2
PWM REGISTER1
PWM REGISTER0
Note 1) For the information on the relation between PWM duty and LED current (ILED), refer to “(9-1) PWM DUTY and LED