datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

NCP1378DR2 데이터 시트보기 (PDF) - ON Semiconductor

부품명
상세내역
일치하는 목록
NCP1378DR2 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Drain
Signal
NCP1378
Timeout
Signal
Drain
Signal
Demag RESTART
Current Sense and Timeout Restart
Timeout
Signal
5 ms
5 ms
Figure 19. When the primary natural ringing becomes too low, the current
sense initiates a new cycle when FB passes the skip level.
Demagnetization Detection
The core reset detection is done by monitoring the
voltage activity on the auxiliary winding. This voltage
features a FLYBACK polarity. The typical detection level
is fixed at 50 mV as exemplified by Figure 20.
7.0
5.0
POSSIBLE
RESTARTS
3.0
1.0
0V
1.0
50 mV
TO INTERNAL
COMPARATOR
Resd
2k
3
ESD
1
4
ESD
Rdem
5
2
Aux
4
1
Figure 20. Core Reset Detection is Done through
a Dedicated Auxiliary Winding Monitoring
An internal timer prevents any restart within 8.0 ms
further to the driver goinglow transition. This prevents the
switching frequency to exceed (1.0/TON + 8.0 ms) but also
Figure 21. Internal Pad Implementation
avoid false leakage inductance tripping at turnoff. In some
cases, the leakage inductance kick is so energetic, that a
slight filtering is necessary.
http://onsemi.com
10

Share Link: 