![](/html/Powerex/51845/page6.png)
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS11037
Intellimod™ Module
Application Specific IPM
50 Amperes/600 Volts
Functional Block Diagram
CBU+ CBU– CBV+ CBV– CBW+ CBW–
VD
HVASIC
LEVEL
GATE DRIVE
SHIFT UV LOCK-OUT
U
UP
VP
LEVEL
GATE DRIVE
SHIFT UV LOCK-OUT
V
WP
UN
VN
LEVEL
SHIFT
GATE DRIVE
UV LOCK-OUT
W
WN
P
GATE DRIVE
UV LOCK-OUT
FO
FAULT
LOGIC
OC/SC
DETECT
AMP
Vamp
GND
N
6