MM1510
Measurement Procedures
Consumption current for
PS
Consumption current for
PS
PS input voltage
Vo l t a g e g a i n
Frequency characteristic
Differential gain
Differential phase
Output dynamic range
ICC1
ICC2
VI
GV
fc
DG
DP
VD
Connect a DC ammeter to the VCC pin and measure.
Connect a DC ammeter to the VCC pin and measure.
Connect a DC ammeter to the VCC pin. Gradually
lower from VC1 =VCC. VC1 voltage when
consumption current is reduced from ICC1 to
110% of ICC2 is VIL. Gradually raise from VC1 =
0V. VC1 voltage when consumption current
increases from ICC2 to 90% of ICC1 is VIH.
From here on, short the ammeter when using it.
Input a 1.0VP-P, 100kHz sine wave to SG1. If TP1
voltage is V1 and TP2 voltage is V2, find GV by the
following formula: GV = 20LOG (V2/V1) dB
In the above GV measurement, if TP2 voltage at
7MHz is V3, find fc by the following formula.
fc = 20LOG (V3/V2) dB
Input a 1.0VP-P staircase to SG1 and measure
differential gain at TP2. APL = 10 ~ 90%
The same as for DG, but measure differential phase.
Input a 100kHz sine wave to SG1. Measure DR, the
maximum amplitude under THD 1%, at TP2.
TEST CIRCUIT
4/5