datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

MH16V645BWJ 데이터 시트보기 (PDF) - MITSUBISHI ELECTRIC

부품명
상세내역
일치하는 목록
MH16V645BWJ Datasheet PDF : 22 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Preliminary Spec.
Specifications subject to
change without notice.
MITSUBISHI LSIs
MH16V645BWJ -5, -6
HYPER PAGE MODE 1073741824 - BIT ( 16777216 - WORD BY 64 - BIT ) DYNAMIC RAM
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Vcc
Supply voltage
VI
Input voltage
VO
Output voltage
IO
Output current
Pd
Power dissipation
Topr
Operating temperature
Tstg
Storage temperature
Conditions
With respect to Vss
Ta=25°C
Ratings
Unit
-0.5~ 4.6
V
-0.5~ 4.6
V
-0.5~ 4.6
V
50
mA
16
W
0~70
°C
-40~125
°C
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Vcc
Supply voltage
Vss
Supply voltage
VIH
High-level input voltage, all inputs
VIL
Low-level input voltage
Note 1 : All voltage values are with respect to Vss
(Ta=0~70°C, unless otherwise noted) (Note 1)
Limits
Min Nom Max
3.0 3.3 3.6
0
0
0
2.0
Vcc+0.3
-0.3
0.8
Unit
V
V
V
V
ELECTRICAL CHARACTERISTICS (Ta=0~70°C, Vcc=3.3V±0.3V, Vss=0V, unless otherwise noted) (Note 2)
Symbol
Parameter
Test conditions
Limits
Min Typ Max
VOH
High-level output voltage
IOH=-2.0mA
2.4
Vcc
VOL
Low-level output voltage
IOL=2.0mA
0
0.4
IOZ
Off-state output current
II
Input current (except /CAS)
Q floating 0V VOUTVcc
-10
10
0VVINVcc+0.3, Other input pins=0V -160
160
I I (CAS) Input current (/CAS)
0VVINVcc+0.3, Other input pins=0V -20
20
Average supply
ICC1 (AV)
current
from Vcc operating
-5
(Note 3,4,5) - 6
/RAS, /CAS cycling
tRC=tWC=min.
output open
1600
1440
ICC2
Supply current from Vcc , stand-by
/RAS=/CAS =VIH, output open
/RAS=/CAS=WEVcc -0.2, output open
16
8
Average supply current
from Vcc
-5
ICC4(AV) Hyper-Page-Mode (Note 3,4,5) - 6
/RAS=VIL,/CAS cycling
tPC=min.
output open
1600
1440
Average supply current from
Vcc
-5
ICC6(AV)
/CAS before /RAS refresh
mode
(Note 3,5)
-6
/CAS before /RAS refresh cycling
tRC=min.
output open
2080
1920
Note 2: Current flowing into an IC is positive, out is negative.
3: Icc1 (AV), Icc3 (AV), Icc4 (AV) and Icc6 (AV) are dependent on cycle rate. Maximum current is measured at the fastest cycle rate.
4: Icc1 (AV) and Icc4 (AV) are dependent on output loading. Specified values are obtained with the output open.
5: Column address can be changed once or less while /RAS=VIL and /CAS=VIH
Unit
V
V
uA
uA
uA
mA
mA
mA
mA
CAPACITANCE (Ta = 0~70°C, Vcc = 3.3V±0.3V, Vss = 0V, unless otherwise noted)
Symbol
Parameter
Test conditions
CI (/CAS) Input capacitance, /CAS input
CI
Input capacitance, except /CAS input
C(DQ) Input/Output capacitance,DATA
C(SCL) Input capacitance, SPD clock
C(SDA) Input/Output capacitance,SPD DATA
C(SA0~3) Input capacitance, SPD address
VI=Vss
f=1MHZ
Vi=25mVrms
Limits
Min Typ Max
Unit
20
pF
130
pF
15
pF
9
pF
9
pF
7
pF
MIT-DS-0240-0.0
MITSUBISHI
ELECTRIC
( 5 / 22 )
28/Jul/`98

Share Link: 