datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

MC-458CA726EFB-A10 데이터 시트보기 (PDF) - Elpida Memory, Inc

부품명
상세내역
일치하는 목록
MC-458CA726EFB-A10 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MC-458CA726
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
Symbol
Test condition
Grade MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1
tRC tRC(MIN.), IO = 0 mA
/CAS latency = 2 -A80
-A10
550 mA 1
550
/CAS latency = 3 -A80
550
-A10
550
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
5 mA
power down mode
ICC2PS CKE VIL(MAX.), tCK =
5
Precharge standby current in ICC2N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
100 mA
non power down mode
Input signals are changed one time during 30 ns.
ICC2NS CKE VIH(MIN.), tCK = , Input signals are stable.
40
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
25 mA
power down mode
ICC3PS CKE VIL(MAX.), tCK =
20
Active standby current in
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
150 mA
non power down mode
Input signals are changed one time during 30 ns.
ICC3NS CKE VIH(MIN.), tCK = , Input signals are stable.
150
Operating current
ICC4 tCK tCK(MIN.)
/CAS latency = 2 -A80
600 mA 2
(Burst mode)
IO = 0 mA
-A10
475
/CAS latency = 3 -A80
725
-A10
625
CBR (Auto) refresh current
ICC5 tRC tRC(MIN.)
/CAS latency = 2 -A80
1,150 mA 3
-A10
1,150
/CAS latency = 3 -A80
1,150
-A10
1,150
Self refresh current
ICC6 CKE 0.2 V
10 mA
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
–5 +5 µA
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
–1.5 +1.5 µA
High level output voltage
VOH IO = –4 mA
2.4
V
Low level output voltage
VOL IO = +4 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6
Data Sheet E0061N10

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]