datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

MC-4516CD642XS-A75L 데이터 시트보기 (PDF) - Elpida Memory, Inc

부품명
상세내역
일치하는 목록
MC-4516CD642XS-A75L Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MC-4516CD642XS
DC Characteristics (Recommended Operating Conditions unless otherwise noted)
Parameter
Symbol
Test condition
MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1, tRC tRC (MIN.)
/CAS latency = 2
560 mA 1
/CAS latency = 3
580
Precharge standby current in ICC2P CKE VIL (MAX.), tCK = 15 ns
8
mA
power down mode
ICC2PS
Precharge standby current in ICC2N
non power down mode
ICC2NS
EActive standby current in
ICC3P
power down mode
ICC3PS
Active standby current in
ICC3N
Onon power down mode
ICC3NS
Operating current
ICC4
L (Burst mode)
CKE VIL (MAX.), tCK =
CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
Input signals are changed one time during 30 ns.
CKE VIH (MIN.), tCK = , Input signals are stable.
CKE VIL (MAX.), tCK = 15 ns
CKE VIL (MAX.), tCK =
CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
Input signals are changed one time during 30 ns.
CKE VIH (MIN.), tCK = , Input signals are stable.
tCK tCK (MIN.), IO = 0 mA
/CAS latency = 2
/CAS latency = 3
8
160 mA
64
40 mA
32
240 mA
160
700 mA 2
860
CBR (Auto) refresh current
Self refresh current
P Input leakage current
Output leakage current
High level output voltage
r Low level output voltage
ICC5
tRC tRC (MIN.)
/CAS latency = 2
1,040 mA 3
/CAS latency = 3
1,080
ICC6 CKE 0.2 V
-**
16 mA
-**L
6.4 mA
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
–8
+8
µA
IO(L) DOUT is disabled, VO = 0 to 3.6 V
–3
+3
µA
VOH IO = –4.0 mA
2.4
V
VOL IO = +4.0 mA
0.4
V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
o addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
duct 3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6
Data Sheet E0116N20

Share Link: 