MAX6412–MAX6420
Low-Power, Single/Dual-Voltage μP Reset Circuits
with Capacitor-Adjustable Reset Timeout Delay
Use the following formula to calculate the externally moni-
tored voltage (VMON_TH):
VMON_TH = VRST x (R1 + R2)/R2
where VMON_TH is the desired reset threshold voltage
and VRST is the reset input threshold (1.26V). Resistors
R1 and R2 can have very high values to minimize current
consumption due to low leakage currents. Set R2 to some
conveniently high value (1MΩ, for example) and calculate
R1 based on the desired monitored voltage, using the
following formula:
R1 = R2 x (VMON_TH/VRST - 1) (Ω)
Manual Reset Input
(MAX6412/MAX6413/MAX6414)
Many μP-based products require manual reset capabil-
ity, allowing the operator, a technician, or external logic
circuitry to initiate a reset. A logic low on MR asserts reset.
Reset remains asserted while MR is low and for the reset
timeout period after MR returns high.
The MR has an internal 20kΩ pullup resistor so it can be
left open if not used. Connect a normally open momentary
switch from MR to ground to create a manual reset func-
tion (external debounce circuitry is not required for long
reset timeout periods).
A manual reset option can easily be implemented with
the MAX6415–MAX6420 by connecting a normally open
momentary switch in parallel with R2 (Figure 2). When
the switch is closed, the voltage on RESET IN goes to
zero, initiating a reset. Similar to the MAX6412/MAX6413/
MAX6414 manual reset, reset remains asserted while the
switch is closed and for the reset timeout period after the
switch is opened.
VMON_TH
VCC
R1
RESET IN
VCC
R2
MAX6415
MAX6420
GND
SRT
Figure 2. Adding an External Manual Reset Function to the
MAX6415–MAX6420
Monitoring Voltages Other than VCC
(MAX6415/MAX6416/MAX6417)
The MAX6415/MAX6416/MAX6417 contain an adjust-
able reset threshold input. These devices can be used
to monitor voltages other than VCC. Calculate VMON_TH
as shown in the Reset Threshold section. (See Figure 3.)
VMON_TH
VCC
R1
RESET IN
VCC
R2
MAX6415
MAX6416
GND MAX6417
SRT
VMON_TH = 1.26 x (R1 + R2)/R2
R1
RESET IN
VCC
R2
MAX6415
MAX6416
GND MAX6417
SRT
Figure 1. Calculating the Monitored Threshold Voltage (VMON_TH)
Figure 3. Monitoring External Voltages