WDCT Power Amplifier
2400 – 2500 MHz
RoHS
Compliant
MAAPSS0066
V2
Features
Ideal for WDCT Applications
Saturated Output Power: +25 dBm Typical
Power Gain: 25 dB Typical
Low Current: 400 mA at PSAT
Micro-Amp Shutdown
Operates from 1.5 V to 4.0 V
Lead-Free 3 mm 12-Lead PQFN Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
Description
The MAAPSS0066 is a three stage power amplifier
designed for Cordless Telephone applications. This
power amplifier is packaged in a standard outline,
lead-free 3 mm 12-lead PQFN plastic package. The
MAAPSS0066 features an integrated bias controller
that allows for micro amp shut down current.
Ordering Information
Part Number
MAAPSS0066
Package
Bulk Packaging
MAAPSS0066TR-3000
3000 piece reel
MAAPSS0066SMB
Sample Test Board
(Includes 5 Samples)
Note: Reference Application Note M513 for reel size
information.
Absolute Maximum Ratings 1,2
Parameter
Absolute Maximum
Input Power
Operating Supply Voltage
Operating Control Voltage
Operating Temperature
+ 5 dBm
+4.0 Volts
+3.0 Volts
-20°C to +85°C
Channel Temperature
+150°C
Storage Temperature
-40°C to +150°C
1. Exceeding any one or combination of these limits may cause
permanent damage to this device.
2. M/A-COM does not recommend sustained operation near
these survivability limits.
Functional Schematic
VCC1
N/C
VCC2
N/C
RF OUT/
VCC3
RF IN
Ven1
RF OUT/
VCC3
RF OUT/
VCC3
Ven2, 3
N/C
N/C
Pin Configuration
PIN No.
1
2
3
4
5
6
7
8
9
10
11
12
Pad3
PIN Name
N/C
RFIN
VEN1
VEN2,3
N/C
N/C
RFOUT / VCC3
RFOUT / VCC3
RFOUT / VCC3
VCC2
N/C
VCC1
GND
Description
No Connection
RF Input
Power Enable
Power Enable
No Connection
No Connection
RF Output, 3rd Stage Supply
RF Output, 3rd Stage Supply
RF Output, 3rd Stage Supply
2nd Stage Supply
No Connection
1st Stage Supply
RF & DC Ground
3. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or