M34116
ELECTRICAL CHARACTERISTICS (Tamb = 0 to 70°C, VCC = 5V ± 5%)
All DC characteristic are valid 250µs after VCC and clock have been applied. CL is the max. capacitive
load and RL the test pull up resistor.
Signal
CK
Up to
4.096MHz
CK
8.192MHz
SYNC
PCM
Input
PCM
Output
(Open
drain)
Symbol
tCK
tWL
tWH
tR
tF
tCK
tWL
tWH
tR
tF
tSL
tHL
tSH
tWH
tS
tH
tPD min.
tPD max.
RESET
WR
RD
tSL
tHL
tSH
tWH
tWL
tWH
tREP
tSH
tHH
tR
tF
tWL
tWH
tREP
tSH
tHH
tR
tF
Parameter
Clock Period
Clock Low Level Width
Clock High Level Width
Rise Time
Fall Time
Clock Period
Clock Low Level Width
Clock High Level Width
Rise Time
Fall Time
Low Level Set-up Time
Low Level Hold Time
High Level Set-up Time
High Level Width
Set-up Time
Hold Time
Propagation Time Low
Level referred to CK
Propagation Time High
level Referred to CK
Low Level Set-up Time
Low Level Hold Time
High Level Set-up Time
High Level Width
Low Level Width
High Level Width
Repetition interval
between active pulses.
High Level st-up time to
active read strobe.
High Level hold time to
active read strobe.
Rise Time
Fall Time
Low Level Width
High Level Width
Repetition interval
between active pulses.
High Level st-up time to
active read strobe.
High Level hold time to
active read strobe.
Rise Time
Fall Time
Test Condition
See note 1
CL = 50pF RL = 1K
note 6
note 3 and 4
note 5
Min.
230
100
100
120
50
50
30
30
30
tCK
35
35
40
Typ.
Max.
25
25
10
10
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
50
30
30
tCK
150
200
500
0
20
180
200
4 tCK
0
20
180
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
60
ns
60
ns
ns
ns
ns
ns
ns
60
ns
60
ns
Notes:
1. With Extra Bit operating mode insert this time becomes 3 tCK.
2. With Extra Bit operating mode insert these times are 80ns longer.
3. With OPCODE (C/D = I), this time becomes 4tck (6tck if E = 1). E: extra bit indication in ”operating mode” instruction.
4. For tone generation instruction, this time becomes 4tck (6tck if E = 1) E: extra bit indication in ”operating mode” instruction.
5. With extra bit operating mode insert, this time becomes 6tck.
6. The initialization routine takes 2 frames time starting from the rising edge of RESET - Any access to the device should take place after the
initialization routine is completed. (2 frames time).