INTEGRATED CIRCUITS DIVISION
LCA125
Single-Pole, Normally Open
OptoMOS® Relay
Parameter
Blocking Voltage
Load Current
On-Resistance (max)
Ratings
300
170
16
Units
VP
mArms / mADC
Features
3750Vrms Input/Output Isolation
Low Drive Power Requirements (TTL/CMOS
Compatible)
High Reliability
Arc-Free With No Snubbing Circuits
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Small 6-Pin Package
Machine Insertable, Wave Solderable
Surface Mount Tape & Reel Version Available
Applications
Telecommunications
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook,
Pocket Size)
Hook Switch
Dial Pulsing
Ground Start
Ringing Injection
Instrumentation
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
Medical Equipment—Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
Pb
e3
Description
LCA125 is a 300V, 170mA, 16, normally open
(1-Form-A) solid state relay that uses optically coupled
MOSFET technology to provide 3750Vrms of input to
output isolation.
Its optically coupled outputs, which use the patented
OptoMOS architecture, are controlled by a highly
efficient GaAIAs infrared LED.
Use the LCA125 to replace mechanical relays,
and gain the superior reliability associated with
semiconductor devices. Because they have no moving
parts, they offer faster, bounce-free switching in a more
compact surface mount or through hole package.
Approvals
UL Recognized Component: File # E76270
CSA Certified Component: Certificate 1172007
Certified to:
EN60950-1: 2006
EN60950-1: 2005
TUV Certificate: B 09 07 49410 004
Ordering Information
Part #
LCA125
LCA125S
LCA125STR
Description
6-Pin DIP (50/Tube)
6-Pin Surface Mount (50/Tube)
6-Pin Surface Mount (1,000/Reel)
Pin Configuration
AC/DC Configuration
1
+ Control
2
– Control
3
Do Not Use
6
Load
5
Do Not Use
4
Load
DC Only Configuration
1
6
+ Control
2
5
– Control
3
4
Do Not Use
+ Load
– Load
Switching Characteristics of
Normally Open (Form A) Devices
Form-A
IF
ILOAD
90%
ton
10%
toff
DS-LCA125-R09