H. RELIABILITY TEST 信賴性測試
No. Item
Test condition
Evaluation standard
After the test the part shall
1.Continuous life test 高溫壽命測試(連續)
The part shall be subjected to 72 hours at +70with 5.0V , 2400Hz
meet specifications
with-out any degradation
in appearance and
applied.
在+70℃環境下,輸入 5.0V , 2400Hz 連續操作 72 小時.
Operating
performance except SPL.
after 4 hours at +25.
1
life test
壽命測試
2.Intermittent life test 室溫壽命測試(間歇)
the SPL should be in
±10dBA compared with
A duty cycle of 1 minute on, 1 minutes off, a minimum of 10000 times initial one.
at room temp.( +25±10) with 5.0V , 2400Hz applied.
經測試後, 靜置於+25
在室溫下(+25±10), 輸入 5.0V , 2400Hz 通電 1 分鐘/斷電 1 分鐘,測 (室溫)環境中 4 小時後,
10000 次循環.
單體除音壓外, 外觀及電
氣特性須符合規格. 輸出
壓變化量須在±10dBA .
TEST CONDITION.
Standard Test Condition :
一般測試條件
:
Judgement Test Condition :
爭議時測試條件
:
a) Temperature : +5 ~ +35b) Humidity : 45-85%
a) 溫度 : +5 ~ +35
b) 濕度 : 45-85%
a) Temperature : +25 ± 2b) Humidity : 60-70%
a) 溫度 : +25 ± 2
b) 濕度 : 60-70%
c) Pressure : 860-1060mbar
c) 氣壓 : 860-1060mbar
c) Pressure : 860-1060mbar
c) 氣壓 : 860-1060mbar
I. Recommended Temperature Profile For Reflow Oven 建議迴焊爐溫度曲線
SMT Reflow Temperature Profile (Pb_Free)
Peak Temp 260°C
255°C
20~40 sec
150°C
°C
217°C
200°C
60~180sec
60~150sec
Time [sec]