datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

CH1788ET 데이터 시트보기 (PDF) - Cermetek Microelectronics

부품명
상세내역
일치하는 목록
CH1788ET
Cermetek
Cermetek Microelectronics Cermetek
CH1788ET Datasheet PDF : 25 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Cermetek Microelectronics, Inc.
CH1788 Surface Mount PLCC 2400bps Modem
Table 5. CH1788 AT Command Set Summary.
Basic
Commands
Function
AT
Attention Code
A
Answer command
A/
Repeat last Command
C
Carrier Detect DCD Signal Monitor
D
Dial Command
E
Off-Line Character Echo Option
H
Switch Hook Control Option
I
Identification Option
K
DCE-DTE Flow Control
L
Fast Connect Option
N
Data Set Ready DSR Signal
Monitor
O
On-Line Command
P
Pulse Dial
Q
Result Code Display Option
R
Data Terminal Ready DTR Monitor
S
S Register Monitor
T
Tone Dialing
V
Verbose / Numeric Result Codes
W
Extended Result Codes
X
Result Code Set/Call Progress
Y
Async. Speed Buffered Option.
Z
Reset
@T
Test Modes
@Z
Power Down
+++
Escape Sequence
PSTN LINE CONNECTION GUIDELINES
1. The CH1788 must be mounted in the final
assembly such that it is isolated from exposure to
any hazardous voltages within the assembly.
Adequate separation and restraint of cables and
cords must be provided.
the RJ-11C jack. Doing so will invalidate the
FCC approval.
7. The CH1788 requires external surge protection.
This is mandatory to maintain FCC Part 68
conveyed approval. Please use only
recommended components and values. Do not
use an MOV or a Transorb.
8. The CH1788, the RJ-11C jack, the protection
circuitry and all PCB traces in between, must be
contained on a PCB with a 94 V-0 flammability
rating.
9. The supplied FCC registration label must be
applied visibly on the outside of the product.
10. The product’s User Manual must provide the user
with instructions for connection and use as
recommended in the FCC Registration Section
below.
CH1788 HANDLING AND ASSEMBLY
RECOMMENDATIONS
The CH1788 contains static-sensitive components
and should only be handled by personnel and in
areas that are properly protected against static
discharge.
Direct Soldering. The CH1788 may be wave
soldered. All CH1788 products are moisture resistant
and will not be harmed by industry standard wave
soldering processes. Cermetek recommends against
socketing the modem for production products.
However, for development purposes a 68 pin PLCC
socket may be used.
2. The circuitry from the CH1788 to the telephone
line interface must be provided in wiring that
carries no other circuitry other than that
specifically allowed in the FCC rules.
3. Connection to phone line should be made
through an approved RJ-11C jack.
FCC REGISTRATION
The CH1788 is registered with the FCC (Federal
Communications Commission) under Part 68. To
maintain the validity of the registration, the end
product supplier must notify to the end user of the
product of several restrictions the FCC places on the
CH1788 and its use.
4. PCB traces from the modem’s RING and TIP pins
to the RJ-11C jack must be 0.1 inch spacing or
greater to one another and 0.2 inch spacing or
greater to all other traces. The traces should
have a nominal width of 0.020 inches or greater.
5. The RING and TIP PCB traces should be as
short as possible and oriented to prevent
coupling other high speed or high frequency
signals present on the host circuit PCB.
In addition to restriction notification, the FCC requires
that Cermetek make all repairs to the CH1788. If
repairs are necessary after installation of the CH1788
in the end product and the end product has been
delivered to the end user, the end product must be
returned to the end product supplier where the
CH1788 can be removed and then forwarded to
Cermetek for repair. The following notice is
recommended and should be included in the end
product’s user manual.
6. No additional circuitry other than that shown may
be connected between the modem module and
2003 Cermetek Microelectronics, Inc.
Page 11
Document No. 607-0018 Revision A2 (07/03)

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]