IN74LV86
MAXIMUM RATINGS*
Symbol
Parameter
Value
Unit
VCC
IIK *1
IOK *2
IO *3
DC supply voltage
Input diode current
Output diode current
Output source or sink current
-0.5 to +5.0
V
±20
mA
±50
mA
±25
mA
ICC
VCC current
±50
mA
IGND GND current
PD
Power dissipation per package: *4
Plastic DIP
SO
±50
mA
mW
750
500
Tstg Storage Temperature
-65 to +150
°C
TL Lead Temperature, 1.5 mm (Plastic DIP Package), 0.3 mm
260
°C
(SO Package) from Case for 4 Seconds
*Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions.
*1 VI < -0.5 V or VI > VCC + 0.5 V.
*2 VO < -0.5 V or VO > VCC + 0.5 V.
*3 -0.5 V < VO < VCC + 0.5 V.
*4 Derating - Plastic DIP: - 12 mW/°C from 70° to 125°C
SO Package: : - 8 mW/°C from 70° to 125°C
RECOMMENDED OPERATING CONDITIONS
Symbol
VCC
VI
VO
TA
tr, tf
Parameter
DC Supply Voltage
DC Input Voltage
DC Output Voltage
Operating Temperature, All Package Types
Input Rise and Fall Time (Figure 1)
1.0 В VCC <2.0 В
2.0 В VCC <2.7 В
2.7 В VCC <3.6 В
3.6 В VCC 5.5 В
Min Max Unit
1.2
5.5
V
0
VCC
V
0
VCC
V
-40 +125
°C
0
500 ns/V
0
200
0
100
0
50
This device contains protection circuitry to guard against damage due to high static voltages or electric fields.
However, precautions must be taken to avoid applications of any voltage higher than maximum rated voltages to this
high-impedance circuit. For proper operation, VIN and VOUT should be constrained to the range GND(VIN or
VOUT)VCC.
Unused inputs must always be tied to an appropriate logic voltage level (e.g., either GND or VCC). Unused
outputs must be left open.