datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

IDT72805LB(1996) 데이터 시트보기 (PDF) - Integrated Device Technology

부품명
상세내역
일치하는 목록
IDT72805LB
(Rev.:1996)
IDT
Integrated Device Technology IDT
IDT72805LB Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
IDT72805/72815/72825 CMOS Dual SyncFIFO
256 x 18-BIT, 512 x 18, and 1024 x 18
COMMERCIAL TEMPERATURE RANGE
PIN DESCRIPTION
Symbol
DA0–DA17
DB0–DB17
RSA
RSB
WCLKA
WCLKB
WENA
WENB
RCLKA
RCLKB
RENA
RENB
OEA
OEB
LDA
LDB
FLA
FLB
WXIA
WXIB
RXIA
RXIB
EFA
EFB
PAEA
PAEB
PAFA
PAFB
FFA
FFB
WXOA/HFA
WXOB/HFB
RXOA
RXOB
QA0–QA17
QB0–QB17
VCC
GND
Name
Data Inputs
Reset
Write Clock
Write Enable
Read Clock
Read Enable
Output Enable
Load
First Load
Write Expansion
Input
Read Expansion
Input
Empty Flag
Programmable
Almost-Empty Flag
Programmable
Almost-Full Flag
Full Flag
Write Expansion
Out/Half-Full Flag
Read Expansion
Out
Data Outputs
Power
Ground
I/O Description
I Data inputs for a 18-bit bus.
I When RS is set LOW, internal read and write pointers are set to the first location of the
RAM array, FF and PAF go HIGH, and PAE and EF go LOW. A reset is required before
an initial WRITE after power-up.
I When WEN is LOW, data is written into the FIFO on a LOW-to-HIGH transition of WCLK,
if the FIFO is not full.
I When WEN is LOW, data is written into the FIFO on every LOW-to-HIGH transition of
WCLK. When WEN is HIGH, the FIFO holds the previous data. Data will not be written
into the FIFO if the FF is LOW.
I When REN is LOW, data is read from the FIFO on a LOW-to-HIGH transition of RCLK, if
the FIFO is not empty.
I When REN is LOW, data is read from the FIFO on every LOW-to-HIGH transition of
RCLK. When REN is HIGH, the output register holds the previous data. Data will not be
read from the FIFO if the EF is LOW.
I When OE is LOW, the data output bus is active. If OE is HIGH, the output data bus will
be in a high-impedance state.
I When LD is LOW, data on the inputs D0–D9 is written to the offset and depth registers
on the LOW-to-HIGH transition of the WCLK, when WEN is LOW. When LD is LOW,
data on the outputs Q0–Q9 is read from the offset and depth registers on the LOW-to-
HIGH transition of the RCLK, when REN is LOW.
I In the single device or width expansion configuration, FL is grounded. In the depth
expansion configuration, FL is grounded on the first device (first load device) and set to
HIGH for all other devices in the daisy chain.
I In the single device or width expansion configuration, WXI is grounded. In the depth
expansion configuration, WXI is connected to WXO (Write Expansion Out) of the
previous device.
I In the single device or width expansion configuration, RXI is grounded. In the depth
expansion configuration, RXI is connected to RXO (Read Expansion Out) of the previous
device.
O When EF is LOW, the FIFO is empty and further data reads from the output are inhibited.
When EF is HIGH, the FIFO is not empty. EF is synchronized to RCLK.
O When PAE is LOW, the FIFO is almost empty based on the offset programmed into the
FIFO. The default offset at reset is 31 from empty for 72805LB, 63 from empty for
72815LB, and 127 from empty for 72825LB.
O When PAF is LOW, the FIFO is almost full based on the offset programmed into the FIFO.
The default offset at reset is 31 from full for 72805LB, 63 from full for 72815LB, and
127 from full for 72825LB.
O When FF is LOW, the FIFO is full and further data writes into the input are inhibited.
When FF is HIGH, the FIFO is not full. FF is synchronized to WCLK.
O In the single device or width expansion configuration, the device is more than half full
when HF is LOW. In the depth expansion configuration, a pulse is sent from WXO to
WXI of the next device when the last location in the FIFO is written.
O In the depth expansion configuration, a pulse is sent from RXO to RXI of the next device
when the last location in the FIFO is read.
O Data outputs for a 18-bit bus.
8 Vcc pins
9 GND pins
3139 tbl 01
5.17
3

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]