datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

GM1117-1.5 데이터 시트보기 (PDF) - Gamma Microelectronics Inc.

부품명
상세내역
일치하는 목록
GM1117-1.5
GAMMA
Gamma Microelectronics Inc. GAMMA
GM1117-1.5 Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
AA
MICROELECTRONICS
Power Management
GM1117
1.0A LOW DROPOUT PRECISION LINEAR REGULATORS
Protection Diodes
When large external capacitors are used with most
linear regulator, it is wise to add protection diodes. If
the input voltage of the regulator is shorted, the out-
put capacitor will discharge into the output of the reg-
ulator. The discharge current depends on the value
of capacitor, output voltage, and rate at which VIN
drops.
Figure 2 (a),(b) Protection Diode Scheme for
Large Output Capacitors
(a) Fixed Version
Output Voltage Sensing
The GM1117 are three terminal regulators. For which,
they cannot provide true remote load sensing. Load
regulation is limited by the resistance of the conductors
connecting the regulator to the load. For best results
the GM1117 should be connected are as shown in
Figure 3.
VIN
VIN
VOUT
GM1117-3.3
Conductor
Parasitic
RC
Resistance
GND
RLOAD
(a) Fixed Version
VIN
C1
IN4002
VIN
VOUT
GM1117-3.3
GND
VOUT
C2
VIN
VIN
VOUT
GM1117-Adj
ADJ
(b) Adjustable Version
RC
R1
R2
Conductor
Parasitic
Resistance
RLOAD
(b) Adjustable Version
VIN
C1
IN4002
VIN
VOUT
VOUT
GM1117-Adj
ADJ
R1 C2
CADJ
R2
In the GM1117 linear regulators, the discharge path
is through a large junction, and protection diodes are
normally not needed. However, damage can occur if
the regulator is used with large output capacitance
values and the input voltage is instantaneously
shorted to ground. In this case, a diode connected
as shown above in Figure 2.
Figure 3 (a),(b) Conductor Parasitic Resistance Effects are
Minimized by this Grounding Scheme For Fixed
and Adjustable Output Regulators
Calculating Power Dissipation and Heat
Sink Requirements
The GM1117 precision linear regulators include thermal
shutdown and current limit circuitry to protect the de-
vices. However, high power regulators normally oper-
ate at high junction temperatures. It is important to cal-
culate the power dissipation and junction temperatures
accurately to be sure that you use and adequate heat
sink. The case is connected to VOUT on the GM1117,
and electrical isolation may be required for some appli-
cations. Thermal compound should always be used
with high current regulators like the GM1117.