datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

E6833A 데이터 시트보기 (PDF) - HP => Agilent Technologies

부품명
상세내역
일치하는 목록
E6833A
HP
HP => Agilent Technologies HP
E6833A Datasheet PDF : 6 Pages
1 2 3 4 5 6
Fast Device Tune Measurement
Measurement method
Allows simultaneous calibration
of a device’s transmitter output
power and receiver input level
across level and frequency in a
single sweep (per frequency
band). The device must operate
in a test mode, which forces it
to transmit a predefined series
of power steps at various
reverse link frequencies, and
simultaneously tune its receiver
to perform measurements (such
as RSSI) of the test set’s signal
at various forward link
frequencies and power levels
Measurement range
–65 dBm/1.23 MHz to
+28 dBm/1.23 MHz
Measurement interval
1.25 ms
Measurement filter
1.23 MHz brick wall
Step size range
5 to 20 ms
Trigger sources
Immediate and RF rise
Output level setting (to be within 0.1 dB of the final power level)
Amplitude switch
< 1 ms, typically < 250 µs
Frequency switch
< 1 ms, typically < 500 µs
within band
Measurement accuracy1 (within 45 dB of expected power with
< 48 hours warm-up before self alignment initiation)
–54 to +28 dBm/1.23 MHz < ±0.75 dB, typically < ±0.3 dB
–61 to < –55 dBm/1.23 MHz < ±0.85 dB, typically < ±0.3 dB
RF source output level range
RF in/out port
–115 dBm/1.23 MHz to
–15 dBm/1.23 MHz
RF out only port
–115 dBm/1.23 MHz to
–5 dBm/1.23 MHz
Composite absolute output level accuracy (< ±10 °C and
< 24 hours from the last alignment, –108 to –15 dBm/1.23 MHz)
RF in/out port
< ±1.0 dB, typically ±0.65 dB
RF out only port
< ±1.0 dB, typically ±0.65 dB
RF output level settling
< 1 ms to be within 0.1 dB of the
final value
1. Additional accuracy error when using RF OUT ONLY port is < ±0.1 dB.