datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

DG4051A 데이터 시트보기 (PDF) - Vishay Semiconductors

부품명
상세내역
일치하는 목록
DG4051A Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DG4051A, DG4052A, DG4053A
Vishay Siliconix
SPECIFICATIONS FOR UNIPOLAR SUPPLIES
Parameter
Analog Switch
Symbol
Test Conditions
Unless Otherwise Specified
VCC = + 3 V, VEE = 0 V
VIN(A, B, C and ENABLE) = 1.4 V, 0.6 Va
Temp.b
Typ.c
- 40 °C to 125 °C - 40 °C to 85 °C
Min.d Max.d Min.d Max.d
Unit
Analog Signal Rangee
VANALOG
Full
0
3
0
3
V
On-Resistance
RON
IS = 1 mA, VD = 1.5 V
Room 175
Full
265
310
265
298
Switch Off
Leakage Current
IS(off)
V+ = + 3.3 V, V- = 0 V
Room ± 0.02 - 1
1
-1
Full
- 50
50
-5
ID(off)
VD = 0.3 V/3.0 V, VS = 3.0 V/0.3 V Room ± 0.02 - 1
Full
- 50
1
50
-1
-5
1
5
1
5
nA
Channel On
Leakage Current
Digital Control
ID(on)
V+ = + 3.3 V, V- = 0 V
VD = VS = 0.3 V/3.0 V
Room ± 0.02 - 1
1
-1
1
Full
- 50
50
-5
5
Input Current, VIN Low
IL
Input Current, VIN High
IH
VIN(A, B, C and ENABLE)
under test = 0.6 V
VIN(A, B, C and ENABLE)
under test = 1.4 V
Full
0.01
-1
1
-1
1
µA
Full
0.01
-1
1
-1
1
Dynamic Characteristics
Transition Time
tTRANS
Room 81
Full
172
172
218
194
Enable Turn-On Time
tON
Enable Turn-Off Time
tOFF
RL = 300 , CL = 35 pF
see figure 1, 2, 3
Room 71
Full
Room 69
Full
151
151
183
167
ns
138
138
161
151
Break-Before-Make
Time Delay
Charge Injectione
Off Isolatione
Channel-to-Channel
Crosstalke
tD
Q
OIRR
XTALK
Vg = 0 V, Rg = 0 , CL = 1 nF
RL = 50 , CL = 1 pF
f = 100 kHz
Room
1
Full
Room 0.5
Room < - 90
Room < - 90
1
pC
dB
Source Off Capacitancee CS(off)
f = 1 MHz
DG4051A Room
4
DG4052A Room
3
DG4053A Room
4
DG4051A Room 14
Drain Off Capacitancee
CD(off)
f = 1 MHz
DG4052A Room
8
pF
DG4053A Room
5
Channel On
Capacitancee
CD(on)
f = 1 MHz
DG4051A Room 19
DG4052A Room 14
DG4053A Room 11
Power Supplies
Power Supply Current
I+
Room 0.05
1
1
Full
10
10
Negative Supply Current
I-
VIN(A, B, C and ENABLE) = 0 V or 3 V
Room
Full
- 0.05
-1
- 10
-1
- 10
µA
Ground Current
IGND
Room - 0.05 - 1
-1
Full
- 10
- 10
Notes:
a. VIN = input voltage to perform proper function.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
6
Document Number: 69828
S10-1383-Rev. E, 21-Jun-10

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]