datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

DF-C10 데이터 시트보기 (PDF) - LEM Industrial

부품명
상세내역
일치하는 목록
DF-C10
LEM
LEM Industrial LEM
DF-C10 Datasheet PDF : 2 Pages
1 2
DC Current transducer DF-C10
For the electronic mesurement of low DC currents, with galvanic
isolation between the primary (High power) and the secondary circuits
(Electronic circuit)
Preliminary
IPN = 10..500mA
Electrical data
Primary nominal
current
IPN (mA.t)
10
20
50
100
300
500
Primary current
range
IP (mA.t)
16
38
80
160
480
800
IOC Overload capacity
VOUT Analog Output signal @ ±IPN
Vc Supply voltage
IC
Current consumption (max)
RL Load resistance
Vd Isolation test voltage1)
Analogue Output
signal
VOUT (V)
0-10
0-10
0-10
0-10
0-10
0-10
Type
DF 0.01 C10
DF 0.02 C10
DF 0.05 C10
DF 0.1 C10
DF 0.3 C10
DF 0.5 C10
30
± 10
± 12...15
20
2
5000
A.t
V
VDC
mA
k
VAC
Features
DC Measurement
Low current transducer
Panel mounting
Bipolar voltage supply
Extended measuring range
Advantages
Accuracy-Dynamic performance data
X
Accuracy2) of reading @±12V, TA=25°C
εL
Linearity2) of IPN
VOE Electrical Offset Voltage @ TA=25°C @IP=0
VOT Thermal drift of VOE @ 0..+70°
tr
Response time @ 90% of IPN
±4
± 0.8
± 50
±100
<140
Large aperture
Good performances in harsh
EMC environment
% High isolation between primary
% and secondary circuits
mV Easy to mount
mV Bipolar
mS No insertion losses
General data
TA Ambient operating temperature
TS Ambient storage temperature
m Mass
Standard
Notes: 1) Between primary and secondary
2) Excludes the electrical offset
LEM Components
0..+70
-25..+85
140
TBD
Applications
DC leakage current
°C
measurement
°C Differential current
g
measurement in DC applica-
tions
Low DC current measurement
Options on request
DIN mounting
020521/0
www.lem.com

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]