MC-4532CD647XFA
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
-A75
Parameter
Symbol
Test condition
MIN. MAX. Unit
Operating current
ICC1 Burst length = 1
tRC ≥ tRC(MIN.), IO = 0 mA
/CAS latency = 2
/CAS latency = 3
1,040 mA
1,080
Precharge standby current in ICC2P CKE ≤ VIL(MAX.), tCK = 15 ns
16
mA
power down mode
ICC2PS CKE ≤ VIL(MAX.), tCK = ∞
16
Precharge standby current in
non power down mode
ICC2N
CKE ≥ VIH(MIN.), tCK = 15 ns, /CS ≥ VIH(MIN.),
Input signals are changed one time during
30 ns.
ICC2NS CKE ≥ VIH(MIN.), tCK = ∞ Input
signals are stable.
Active standby current in
ICC3P CKE ≤ VIL(MAX.), tCK = 15 ns
320 mA
128
80
mA
power down mode
ICC3PS CKE ≤ VIL(MAX.), tCK = ∞
64
Active standby current in non
power down mode
ICC3N
CKE ≥ VIH(MIN.), tCK = 15 ns, /CS ≥ VIH(MIN.),
Input signals are changed one time during
30 ns.
ICC3NS CKE ≥ VIH(MIN.), tCK = ∞, Input signals are stable.
480 mA
320
Operating current
ICC4 tCK ≥ tCK(MIN.)
/CAS latency = 2
1,200 mA
(Burst mode)
IO = 0 mA
/CAS latency = 3
1,480
CBR (Auto) refresh current
ICC5 tRC ≥ tRC(MIN.)
/CAS latency = 2
2,080 mA
/CAS latency = 3
2,160
Self refresh current
ICC6 CKE ≤ 0.2 V
32
mA
Input leakage current
Output leakage current
II(L) VI = 0 to 3.6 V, All other pins not under
test = 0 V
– 16
+ 16 µA
CKE1 – 500 +500
IO(L) DOUT is disabled, VO = 0 to 3.6 V
–3
+3
µA
High level output voltage
VOH IO = – 4.0 mA
2.4
V
Low level output voltage
VOL IO = + 4.0 mA
0.4
V
Notes
1
2
3
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6