CY22393, CY22394, CY22395
Writing Multiple Bytes
To write multiple bytes at a time, the master must not end the
write sequence with a STOP condition. Instead, the master
sends multiple contiguous bytes of data to be stored. After each
byte, the slave responds with an acknowledge bit, the same as
after the first byte, and accepts data until the STOP condition
responds to the acknowledge bit. When receiving multiple bytes,
the CY22393, CY22394, and CY22395 internally increment the
register address.
Read Operations
Read operations are initiated the same way as Write operations
except that the R/W bit of the slave address is set to ‘1’ (HIGH).
There are three basic read operations: current address read,
random read, and sequential read.
Current Address Read
The CY22393, CY22394 and CY22395 have an onboard
address counter that retains “1” more than the address of the last
word access. If the last word written or read was word ‘n’, then a
current address read operation returns the value stored in
location ‘n+1’. When the CY22393, CY22394 and CY22395
receive the slave address with the R/W bit set to a ‘1’, they issue
an acknowledge and transmit the 8-bit word. The master device
does not acknowledge the transfer, but generates a STOP
condition, which causes the CY22393, CY22394 and CY22395
to stop transmission.
Random Read
Through random read operations, the master may access any
memory location. To perform this type of read operation, first set
the word address. Do this by sending the address to the
CY22393, CY22394 and CY22395 as part of a write operation.
After the word address is sent, the master generates a START
condition following the acknowledge. This terminates the write
operation before any data is stored in the address, but not before
setting the internal address pointer. Next, the master reissues
the control byte with the R/W byte set to ‘1’. The CY22393,
CY22394 and CY22395 then issue an acknowledge and transmit
the 8-bit word. The master device does not acknowledge the
transfer, but generates a STOP condition which causes the
CY22393, CY22394 and CY22395 to stop transmission.
Sequential Read
Sequential read operations follow the same process as random
reads except that the master issues an acknowledge instead of
a STOP condition after transmitting the first 8-bit data word. This
action increments the internal address pointer, and subsequently
outputs the next 8-bit data word. By continuing to issue acknowl-
edges instead of STOP conditions, the master serially reads the
entire contents of the slave device memory. Note that register
addresses outside of 08H to 1BH and 40H to 57H can be read
from but are not real registers and do not contain configuration
information. When the internal address pointer points to the FFH
register, after the next increment, the pointer points to the 00H
register.
Figure 2. Data Transfer Sequence on the Serial Bus
SCLK
SDAT
START
Condition
Address or
Acknowledge
Valid
Data may
be changed
STOP
Condition
Document #: 38-07186 Rev. *D
Page 10 of 19
[+] Feedback