CXG1096FN
Electrical Characteristics
These specifications are when the Sony's recommended evaluation board shown on page 6 is used.
1. Power Amplifier Block + Antenna Switch Transmitter Block
These specifications are common to the ANT1 transmission and ANT2 transmission.
Unless otherwise specified: VDD = 3V, IDD = 150mA, POUT = 20.2dBm, f = 1.9GHz
When ANT1 transmission: VCTL1 = 3V, VCTL2 = 0V
When ANT2 transmission: VCTL1 = 0V, VCTL2 = 3V
(Ta = 25°C)
Item
Symbol
Measurement conditions Min. Typ. Max. Unit
Current consumption
Gate voltage adjustment value
Output power
Power gain
Adjacent channel leak power ratio
(600 ± 100kHz)
Adjacent channel leak power ratio
(900 ± 100kHz)
Occupied bandwidth
2nd-order harmonic level
3rd-order harmonic level
IDD
VGG
POUT
GP
Measured with the ANT pin
150
0.04
20.2
36 40
mA
0.6 V
dBm
dB
ACPR600kHz Measured with the ANT pin
–63 –55 dBc
ACPR900kHz Measured with the ANT pin
OBW
—
—
Measured with the ANT pin
Measured with the ANT pin
Measured with the ANT pin
–70 –60 dBc
250 275 kHz
–25 dBc
–25 dBc
2. Antenna Switch Receiver Block + Low Noise Down Conversion Mixer Block
These specifications are common to the ANT1 reception and ANT2 reception.
Unless otherwise specified: VDD = 3V, RF1 = 1.90GHz/–35dBm, LO = 1.66GHz/–15dBm
When ANT1 reception: VCTL1 = 0V, VCTL2 = 3V
When ANT2 reception: VCTL1 = 3V, VCTL2 = 0V
(Ta = 25°C)
Item
Current consumption
Conversion gain
Noise figure
Input IP3
Image suppression ratio
1/2 IF suppression ratio
2 × LO–IF suppression ratio
2 × LO+IF suppression ratio
LO to ANT leak
Symbol
IDD
GC
NF
IIP3
IMR
1/2IFR
—
—
PLK
Measurement conditions
When no signal
When a small signal
When a small signal
∗1
RF2 = 1.42GHz/–35dBm
RF2 = 1.78GHz/–35dBm
RF2 = 3.08GHz/–35dBm
RF2 = 3.56GHz/–35dBm
Min. Typ. Max. Unit
5.5 7.5 mA
17 19.5
dB
4.4 5.5 dB
–17 –12
dBm
25 40
dBc
41 47
dBc
39 45
dBc
34 65
dBc
–50 –40 dBm
∗1 Conversion from IM3 compression ratio during FR1 = 1.9000GHz/–35dBm and FR2 = 1.9006GHz/–35dBm input.
–3–