CS4220 CS4221
DIF0, DIF1
10,11
Digital Interface Format (Input) - The required relationship between the left/right clock, serial
clock and serial data is defined by the Digital Interface Format. The options are detailed in Fig-
ures 8 - 11.
DIF1
0
0
1
1
DIF0
DESCRIPTION
0 I2S, up to 24-bit data
1 Left Justified, up to 24-bit data
0 Right Justified, 24-bit Data
1 Right Justified, 20-bit Data
FORMAT
0
1
2
3
FIGURE
8
9
10
11
Table 3. Digital Interface Format - DIF1 and DIF0
DEM0, DEM1
12,18 De-Emphasis Select (Input) - Controls the activation of the standard 50/15 µs de-emphasis
filter. 32, 44.1, or 48 kHz sample rate selection defined in Table 4.
DEM0
0
0
1
1
DEM1
0
1
0
1
De-Emphasis
32 kHz
44.1 kHz
48 kHz
Disabled
Table 4. De-emphasis Control
VL
AINR-, AINR+
AINL-, AINL+
VA
AGND
AOUTR-,
AOUTR+
AOUTL-, AOUTL+
RST
13
16,17
19,20
21
22
23, 24
25, 26
27
Digital Logic Power (Input) - Positive power supply for the digital interface section. Typically
3.0 to 5.0 VDC.
Differential Right Channel Analog Input (Input) - The full scale analog input level (differen-
tial) is specified in the Analog Characteristics specification table and may be AC coupled or DC
coupled into the device, see Figure 12 for optional line input buffer.
Differential Left Channel Analog Input (Input) - The full scale analog input level (differential)
is specified in the Analog Characteristics specification table and may be AC coupled or DC
coupled into the device, see Figure 12 for optional line input buffer.
Analog Power (Input) - Positive power supply for the analog section. Nominally +5 Volts.
Analog Ground (Input) - Analog ground reference.
Differential Right Channel Analog Output (Output) - The full scale analog output level (dif-
ferential) is specified in the Analog Characteristics specification table.
Differential Left Channel Analog Output (Output) - The full scale analog output level (differ-
ential) is specified in the Analog Characteristics specification table.
Reset (Input) - When low, the device enters a low power mode and all internal registers are
reset, including the control port. When high, the control port becomes operational and normal
operation will occur.