datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

OMR7812ST 데이터 시트보기 (PDF) - Omnirel Corp => IRF

부품명
상세내역
일치하는 목록
OMR7812ST Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
OMR7805SR
OMR7812SR
OMR7815SR
OMR7805ST
OMR7812ST
OMR7815ST
OMR7805NM
OMR7812NM
OMR7815NM
OMR7805NH
OMR7812NH
OMR7815NH
OMNIREL’S RADIATION TEST PROCEDURE
Radiation Testing is performed on a single wafer by wafer basis.
Each wafer is identified and a random sample of 5 die per wafer is selected.
The die are then individually assembled in a hermetic package, data logged, electrically
tested, hi-rel screened and then submitted to radiation testing.
The packaged die are submitted to Steady State Total Dose radiation per Method 1019,
Condition A, at a dose rate of 50 RAD/sec biased at maximum supply voltage.
Final electrical test is performed within two hours of both Total Dose Radiation level from a
Cobalt 60 source and 168 hr, 100°C annealing process. Read and record data
including two non-radiated control samples.
The wafer is then qualified only if samples from wafers meet full electrical specifications
after 150% of total dose rating as specified in each product data sheet.
Omnirel’s controlling specifications are as follows: For Voltage Regulators the
controlling specification is MIL-PRF- 38534/MIL-STD-883. For Rectifiers/Schottky the
controlling specification is MIL-PRF-19500/MIL-STD-750.
AVAILABLE PRODUCT SCREENING
Screen
Standard Class Level Screening
Per MIL-PRF-38535
*Level B
*Level S
Wafer Lot Acceptance
Non-destructive Bond Pull
Pre-Cap Visual Inspection
Temperature Cycle
Constant Acceleration
Visual Inspection
PIND Test
Serialization
Pre-Burn-In Electrical
Burn-In
Interim Electrical
PDA Calculations
Final Electrical
Fine & Gross Seal
Radiographic
Conformance Inspection**
Final Visual Inspection
Test Method
-----
-----
2010
1010
2001
-----
-----
-----
Data Sheet
1015/160 hrs.
-----
5% Functional
Data Sheet
1014
-----
GR A
2009
Required Test Method Required
-----
-----
100%
100%
100%
100%
-----
-----
100%
100%
-----
Lot
100%
100%
-----
100%
Sample
5007
-----
2010
1010
2001
-----
2020
-----
Data Sheet
1015/240hrs.
Data Sheet
5% Functional
Data Sheet
1014
2012/Two Views
GR A
2009
100%
-----
100%
100%
100%
100%
100%
100%
100%
100%
100%
Lot
100%
100%
100%
100%
Sample
*Note: For “B” Level Screening add “M” to part number, for “S” Level Screening add “S” to part
number. See Part Number Designator.
** Note: Additional conformance inpsection testing, i.e. Group B,C & D optional.

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]