BUZ 326
Electrical Characteristics, at Tj = 25°C, unless otherwise specified
Parameter
Symbol
Values
Unit
min.
typ.
max.
Reverse Diode
Inverse diode continuous forward current IS
TC = 25 °C
-
Inverse diode direct current,pulsed
ISM
TC = 25 °C
-
Inverse diode forward voltage
VSD
VGS = 0 V, IF = 22 A
-
Reverse recovery time
trr
VR = 100 V, IF=lS, diF/dt = 100 A/µs
-
Reverse recovery charge
Qrr
VR = 100 V, IF=lS, diF/dt = 100 A/µs
-
-
-
1
280
3
A
10.5
42
V
1.4
ns
-
µC
-
Semiconductor Group
4