datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

CY7C1324(1999) 데이터 시트보기 (PDF) - Cypress Semiconductor

부품명
상세내역
일치하는 목록
CY7C1324
(Rev.:1999)
Cypress
Cypress Semiconductor Cypress
CY7C1324 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
CY7C1324
AC Test Loads and Waveforms[10]
OUTPUT
Z0 =50
RL =50
VL =1.5V
(a)
2.5V
OUTPUT
5 pF
INCLUDING
JIG AND
SCOPE
R1
2.5V
R2
10%
GND
2.5 ns
(b)[9]
13243
ALL INPUT PULSES
90%
90%
10%
2.5 ns
13244
Switching Characteristics Over the Operating Range[10]
-117
-100
-90
-50
Parameter
Description
Min. Max. Min. Max. Min. Max. Min. Max. Unit
tCYC
Clock Cycle Time
8.5
10
11
20
ns
tCH
Clock HIGH
3.0
4.0
4.5
4.5
ns
tCL
Clock LOW
3.0
4.0
4.5
4.5
ns
tAS
Address Set-Up Before CLK Rise
2.0
2.0
2.0
2.0
ns
tAH
Address Hold After CLK Rise
0.5
0.5
0.5
0.5
ns
tCDV
Data Output Valid After CLK Rise
7.5
8.0
8.5
11.0 ns
tDOH
Data Output Hold After CLK Rise
2.0
2.0
2.0
2.0
ns
tADS
ADSP, ADSC Set-Up Before CLK Rise
2.0
2.0
2.0
2.0
ns
tADH
ADSP, ADSC Hold After CLK Rise
0.5
0.5
0.5
0.5
ns
tWES
BWS[1:0], GW,BWE Set-Up Before CLK Rise 2.0
2.0
2.0
2.0
ns
tWEH
BWS[1:0], GW,BWE Hold After CLK Rise
0.5
0.5
0.5
0.5
ns
tADVS
ADV Set-Up Before CLK Rise
2.0
2.0
2.0
2.0
ns
tADVH
ADV Hold After CLK Rise
0.5
0.5
0.5
0.5
ns
tDS
Data Input Set-Up Before CLK Rise
2.0
2.0
2.0
2.0
ns
tDH
Data Input Hold After CLK Rise
0.5
0.5
0.5
0.5
ns
tCES
Chip Enable Set-Up
2.0
2.0
2.0
2.0
ns
tCEH
tCHZ
tCLZ
tEOHZ
tEOLZ
Chip Enable Hold After CLK Rise
Clock to High-Z[11,12]
Clock to Low-Z[11,12]
OE HIGH to Output High-Z[11,13]
OE LOW to Output Low-Z[11,13]
0.5
0.5
0.5
0.5
ns
3.5
3.5
3.5
3.5 ns
0
0
0
0
ns
3.5
3.5
3.5
3.5 ns
0
0
0
0
ns
tEOV
OE LOW to Output Valid
3.5
3.5
3.5
3.5 ns
Notes:
9. R1=1667and R2=1538for IOH/IOL= 4/8mA, R1=521and R2=481for IOH/IOL= 2/2mA.
10. Unless otherwise noted, test conditions assume signal transition time of 2.5ns or less, timing reference levels of 1.25V, input pulse levels of 0 to 2.5V, and
output loading of the specified IOL/IOH and load capacitance. Shown in (a) and (b) of AC test loads.
11. tCHZ, tCLZ, tEOHZ, and tEOLZ are specified with a load capacitance of 5 pF as in part (b) of AC Test Loads. Transition is measured ± 200 mV from steady-state voltage.
12. At any given voltage and temperature, tCHZ (max) is less than tCLZ (min).
13. This parameter is sampled and not 100% tested.
8

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]