SAW Components
B7305
IF Filter for Mobile Communication
190 MHz
Data Sheet
Test matching network 1 for unbalanced operation in 50-Ω environment (element values de-
pend on PCB layout):
Ls1 = 180 nH
Lp2 = 100 nH
Lp3 = 150 nH
Ls4 = 200 nH
Coils: Coilcraft 1008HQ
Test matching network 2 for balanced operation in 50-Ω environment (element values depend
on PCB layout):)
Cs1 = Cs6 = 4.7 pF
Cp2 = Cp5 = tbd
Lp3 = 47 nH
Lp4 = 68 nH
Coils: Coilcraft 1008HQ
Transformers: 1:4 Toko
616DB1004
5 July 26, 2002